2-12
2.7.6 HiD 2033/2034 I/P Driver, Loop Powered
Hazardous Area Signal (Output)
Output
4-20 mA
on a load of 0 to 500
Ω
max
Load effect
≤
0.2 %
of full scale from 0 to 500
Ω
Output ripple
40
µ
A peak to peak
Response time
50 msec
10 to 90% step change
Safe Area Signal (Input)
Input voltage
7-30 V
Powered by the loop, reverse polarity protected
Input current
4-20 mA
Powered by the loop
Voltage drop-out
7 V
@ 20 mA and 500
Ω
load
Open circuit consumption
< 0.8 mA
@ 24 V
Power dissipation
0.14 W
@ 20 mA (per channel)
Performance at Reference Conditions
Calibration accuracy
<
±
0.1 %
of full scale
Linearity
<
±
0.1 %
of full scale
Temperature drift
<
±
0.01 %/°C
Selector switches
None
LED Indicators
None