2-11
2.7.5 HiD 2031/2032 I/P Driver, Bus Powered
DC supply
Current consumption
35 mA
@ 24 V, 20 mA output (per channel)
Power dissipation
0.75 W
@ 24 V (per channel)
Hazardous Area Signal (Output)
Output
4-20 mA
on a load of 0 to 750
Ω
max
Load effect
≤
0.1 %
of full scale from 0 to 750
Ω
Output ripple
15 mVrms
Response time
50 msec
10 to 90% step change
Safe Area Signal (Input)
Input current
4-20 mA
reverse polarity protected
Input drop-out
< 4 V
with field wiring intact
Input current
< 1.2 mA
with field wiring open
Performance at Reference Conditions
Calibration accuracy
<
±
0.1 %
of full scale
Linearity
<
±
0.1 %
of full scale
Temperature drift
<
±
0.01 %/°C
Selector switches
None
LED Indicators
Power ON
Green