Euro 500TE Handy
© Elcom, s. r. o.
22
ECR programming manual
Flag 7 - Limit and value of the percent surcharge
Flag 8 - Limit and value of the percent discount
Flag 9 - Time setting
Flag 10 - Date setting
Electronic journal flags programming
Digit
Default value
Meaning
Valid values
1–2
(left)
00
Limit for manual entry of surcharges
during registration
00–99
3–6
(right)
0000
Pre-programmed surcharge value
(enter with two decimal places, e. g.
enter 10 as 1000)
0000–9999
Digit
Default value
Meaning
Valid values
1–2
(left)
00
Limit for manual entry of discounts
during registration
00–99
3–6
(right)
0000
Pre-programmed value of discount
(enter with two decimal places, e. g.
enter 10 as 1000)
0000–9999
Table
3.7
>
Meaning of the 7t
system flag.
Table
3.8
>
Meaning of the 8t sys-
tem flag.
Digit Default value
Meaning
Valid values
1–2
12
Hours
00–23
3–4
00
Minutes
00–59
Table
3.9
>
Meaning of the 9t sys-
tem flag.
Digit Default value
Meaning
Valid values
1–2
01
Day
01–31
3–4
01
Month
01–12
5–6
01
Year
00–99
Table
3.10
>
Meaning of the 10t
system flag.
Electronic journal flags program-
ming procedure
The electronic journal flags are data which en-
able the user to set particular electronic journal
functions.
Electronic journal flags programming process:
1) Enter the programming mode “P” by press-
ing
4A
.
2) Press the
KB
button (
Per cent dis-
count
).
3) After entering proper flag values, store
them by pressing the
D
(
Subtotal
).
The programming of the next flag follows.
Continue until all necessary flags have been
programmed.
4) Programmed flag settings may be printed
by pressing the
C
(
Check
) button.
5) Finish the programming by pressing the
E
(
Total
) button.
1. el.jorunal flag
00111