31
GENERAL
– The connection to the electrical
network must be carried out by quali-
fied personnel and must be according
to existing norms.
– The appliance must be connected to
the electrical network verifying above
all that the voltage corresponds to the
value indicated on the specifications
plate and that the cables section of the
electrical plant can bear the load
which is also indicated on the plate.
– The bi-polar plug must be connected
to an outlet connected to the groun-
ding unit in conformity to security
norms.
– If the oven is to be connected directly
to the mains, it must be placed with
an omnipolar switch with minimum
opening between the contacts of 3 mm
between the appliance and the mains.
– The power supply cable must not
touch the hot parts and must be posi-
tioned so that it does not exceed 75°C
at any point.
– Once the oven has been installed, the
switch or socket must always be
accessible.
– If the power supply cable is damaged
it must be substituted by a suitable
cable available in the after sales servi-
ce.
– Voltage: 230 V
~
50 H
Z
The connection of the appliance to
the grounding unit is mandatory.
The manufacturer declines every
responsability for any inconve-
nience resulting from the inobser-
vance of this condition.
Electrical section
99
SUBSTITUTION OF THE OVEN
AND GRILL ELEMENTS
The substitution of the electrical ele-
ments of the oven and the grill are done
in the following way:
– Dismount the back panel of the
appliance
– Unhook the electrical connections of
the broken elements
– Unscrew the screw that fasten the ele-
ment
– Remove the element from the inside
of the muffle. For the lower element
lift the bottom entrance of the oven
– Effect the substitution
– Re-mount, being particularly careful of
the grounding of all the electrical com-
ponents.
FEEDER CABLE SECTION TYPE HO5RR-F
230 V
3 x 1,5 mm
2
Before effecting any intervention
on the electrical parts the applian-
ce must be disconnected from the
network.