EL.MO. Spa PREGIO Series User Manual Download Page 7

7

Area 1

Arm: 123--678

If you press key 8 again, sector 8 will be excluded from sec-

tors proposed.

Per sectors group:

Press a number key to change sectors proposed for arming 

for that specific key according to the following table:

Status BEFORE pressing a 

sector key

Status AFTER having pressed 

a sector key

At least one sector (but not 

all) among those associated 

to that key is proposed for 

arming

All sectors associated to that 

key are proposed for arming 

(as long as they are authorised 

for that user)

All sectors associated to that 

key are proposed for arming

No sectors associated to that 

key are proposed for arming 

(as long as they are authorised 

for that user)

If sectors proposed for arming are

Area 1

Arm: 123--67-

and sector key S2 has sectors 3, 4, and 5 associated (all 

authorised for the user too), when you press sector key S2 

items proposed for arming will change:

Area 1

Arm: 1234567-

 

– When finished, press 

OK

 to start arming, 

STOP

 to cancel 

it.

 

– If exit time has been set, it will be marked by beep sounds: 

leave the protected areas within the set time walking 

through the path set.

At the end of exit time, sectors proposed will be armed (sec-

tor keys remains lighted unless the option 

Hide Arming Sta-

tus

 is enabled).

2.4.5   Fast arming - 4 areas / 4 sectors mode

If two specific options are enabled, sectors can be armed 

without entering the user code.

Arming with sector key + OK

The option 

Activate fast arming

 in BrowserOne has to 

be activated.

 

– Press sector key of the sector to be armed (the sector can 

be armed if it is authorised at least to one user). The key 

will start blinking.

Sector S1.A1
FAST ARMING?

 

– Press 

OK

 to confirm (if not, the procedure will be can-

celled after 5s).

 

– If an exit time has been set, leave the protected areas 

within the set time.

When during the procedure another sector key is pressed, 

the sector to be armed will be changed.

The procedure will be cancelled if you press the key of a 

sector that cannot be armed.

Arming with double pressure

The option 

"Fast arming/output manoeuvre" has to 

enabled with the double pressure of the sector key

 

in BrowserOne.

 

– Press sector key of the sector to be armed (the sector can 

be armed if it is authorised at least to one user). The key 

will start blinking.

Sector S1.A1
FAST ARMING?

 

– Press the key again.

 

– If an exit time has been set, leave the protected areas 

within the set time.

The procedure will be cancelled if you press the key of a 

sector that cannot be armed.

2.4.6   Fast arming - 8/16 sectors per area mode

Fast arming option can be enabled under ‘8/16 sectors per 

area’ mode (if checked during system configuration); to do 

so, press sector key + OK, or press sector key twice (as ex-

plained in the previous paragraph 2.4.5 

p. 7.

Sectors associated to that sectors key will be armed as long 

as they are also authorised for the user.

2.4.7   Disarming

When system is armed:

Summary of Contents for PREGIO Series

Page 1: ...l control units are protected against the cover opening and removal from wall Icons used in this manual Example of messages on keypad display Fri01 09 17 9 00 Area 1 Keys typing Usage example Manual contents Keypads usage operating mode from keypad cap 2 p 1 Proximity keys usage operating mode from keypad cap 3 p 11 Remote controls usage operating mode with remote control cap 4 p 13 GSM and phone ...

Page 2: ...or key provides information about arming status of corresponding sectors Key status Indication OFF All sectors associated to the key are disarmed ON All sectors associated to the key are armed Fast blinking All sectors associated to the key are armed with maximum security Fast blinking alternate to steady light At least one sector associated to the key is armed but not all Slow blinking Exit time ...

Page 3: ...It indicates general alarm OFF no alarm events ON alarm in progress active relay Blinking alarm memories To reset alarm memories arm and disarm the system 4 Tamper LED It indicates tamper status OFF no tampering zones ON tamper alarm in progress active relay Blinking tamper alarm memories To reset alarm memo ries arm and disarm the system Once the system has been armed if the option Visual isation...

Page 4: ...If during installation the option Enable keypad locking for error code has been enabled the keypad will be blocked after the wrong code has been entered for three times The following message will be displayed for 90 seconds TEMPORARY DISABLEMENT Further options are available for associating tamper events generation with wrong codes typing Please see product programming manual 2 3 Display the statu...

Page 5: ...ction devices detectors magnet ic contacts etc During unit configuration some zones can be included into exit path After system arming users can leave the premis es within a set time exit time through the exit path without triggering an alarm event Exit path zones can be set as exit door when users exit and close the door the remaining exit time will reset and the unit will arm The subsequent open...

Page 6: ...annot be armed the arming procedure will be stopped 2 4 4 System arming with sectors selection 8 16 sectors per area mode Under 8 16 Sectors per area mode sector keys are associat ed to sectors group Sector keys arm disarm sector groups The key sectors as sociation is made during setup Key in user code Press OK Keys of sectors proposed for arming for a specific user will blink in the currently ope...

Page 7: ...be armed without entering the user code Arming with sector key OK The option Activate fast arming in BrowserOne has to be activated Press sector key of the sector to be armed the sector can be armed if it is authorised at least to one user The key will start blinking Sector S1 A1 FAST ARMING Press OK to confirm if not the procedure will be can celled after 5s If an exit time has been set leave the...

Page 8: ...m arm disarm Forced arming through keypad If the option Activate arming lock is enabled in Browse rOne system arming will be denied if some fault conditions occur When the arming is denied due to a dialler failure or lack of supervision users can force the arming only through the keypads controlling the areas involved in the arming denied When forced arming is allowed the following message will be...

Page 9: ...press STOP repeatedly after an operation you may be asked to save changes SAVE CHANGES Ok Yes No While in user menu the 4 LED indicators will blink simultaneously The user menu lists the following items on the right the number of the paragraph with details on the items MAINTENANCE BYPASS ZONES 2 5 1 p 9 INSTALLER AUTH 2 5 2 p 9 OUTPUT CONTROL 2 5 3 p 10 MANAGE SIM BAL 2 5 4 p 10 CLOCK SETUP 2 5 5 ...

Page 10: ...or press STOP to exit the menu without saving 2 5 6 Clock calibration Use this menu to manually adjust the difference in time oc curred over a month between the control unit clock and the standard one Use arrow keys or to go to CLOCK CALIBR option Press OK to enter the menu Use arrow keys or to increase decrease seconds per month 5s month steps Press OK to save and exit the menu or press STOP to e...

Page 11: ...acti vated for 6 seconds and the activation can be interrupted by pressing key Once the test is completed press STOP to exit test step Use arrow keys or to go to the next step DIALLER TEST Press OK to start the test The dialler activates and the message TEST CALL will be displayed Press OK again to start the test Wait for test to be com pleted the message NOT EXECUTAB will be displayed if the dial...

Page 12: ...age Before proceeding please see arming general information paragraph 2 4 1 p 5 3 2 1 System arming Place the proximity key near the sensitive area onto reader or keypad The pre arming time will start around 5s if there are sector keys users can modify sectors proposed for arm ing Please see paragraph 2 4 3 p 5 When the pre arming time elapses the exit time will start if set Leave the protected ar...

Page 13: ...ock 4 REMOTE CONTROLS USAGE Remote control devices can be used to arm either totally or partially and disarm systems Remote controls have to be learned to a specific device Remote control Device ATLANTE4 ATLANTE6 RIVERRF ATLANTE4PLUS RIVERRFPLUS ATLANTE2K GATEWAY2K 4 1 Function keys The following image refers to ATLANTE2K device Other de vices may not feature the same function keys A Key TOTAL ARM...

Page 14: ...s not allowed because of dialler fault or lack of supervision events users can force system arming only us ing control devices that control areas involved in the arming lock Within 15 seconds to force arming press again the re mote control key previously selected Bypassed detectors will not cause system lock 5 GSM AND PHONE COMMUNICATIONS PREGIO1000 PREGIO1000BM and PREGIO2000 control units suppor...

Page 15: ...anced settings The installer can set advanced settings using BrowserOne software 5 6 1 Dialler block at disarming Users can require to block phone communications voice and digital caused by sectors disarming Dialler block function is available in Options menu in BrowserOne If dialler block is removed the phone dialler will activate when the first event generated after the removal occurs 5 6 2 Limi...

Page 16: ...g an SMS text with S 3 7 E CONNECT e Connect is a supervision software for EL MO intrusion de tection systems It allows users to control and manage their systems via the Internet a PC or a smartphone application Operations with e Connect software check control unit status anomalies tamper events alarms arm disarm procedures read events log enable disable outputs For the correct use of the software...

Page 17: ...ity mode and a user with max security prop erty performs a disarm the Weekly Programmer Max Security property remains active Therefore at the next control unit arming it will be armed with Max Se curity property even if the arming is performed by a user without the Max Security property However if the disarming is performed via weekly programmer Max Security Reset function the sector property will...

Page 18: ...e unit and the unit will reply with another SMS text The command sent will be accepted only if sent by a number on the unit phone number list 9 1 SMS structure SMS text shall be in the following form C nnnnnn X X where nnnnnn code of the user sending the SMS 6 digits X X code of the command see table Leave an empty space between C nnnnnn and X X With a single SMS text it is possible to send up to ...

Page 19: ...ser TAMPER ALARM MEMORY Tamper alarm memory at one of the areas authorised for the user INTRUSION ALARM Intrusion alarm at one of the areas authorised for the user INTRUSION ALARM MEMORY Intrusion alarm memory at one of the areas authorised for the user PANEL ANOMALY One of the areas authorised for the user signals an anomaly or there is a memory for such event GSM ON GSM module on GSM TURNING OFF...

Page 20: ...ctors disarmed A DENIED Arming impossible D DENIED Disarming impossible 9 3 2 GSM ON OFF Replying SMS Indication GSM ON GSM module on GSM TURNING OFF GSM module is turning off G DENIED GSM on off functions disabled or the user is not authorised for Small Maintenance 9 3 3 Remote listening request Replying SMS Indication REMOTE LISTENING REQ Command M ON recognised 9 3 4 Activate deactivate outputs...

Page 21: ...w or absent It may be necessary to replace battery protection fuse ANOMALY Mains failure Mains failure the unit is powered by the battery only ANOMALY Tel Line Fault Phone line not detected or absent ANOMALY No GSM Registr SIM card missing or disabled or PIN code active KEYP RD TAMPER Keyp Rd 1 Keypad or reader the number of which is indicated signals a tamper event ANOMALY SIM Balance SIM balance...

Page 22: ...22 ...

Page 23: ...uress mode p 12 3 2 4 System forced arming p 13 4 REMOTE CONTROLS USAGE P 13 4 1 Function keys p 13 4 2 Operation with remote controls p 13 4 2 1 System arming p 13 4 2 2 Disarming p 14 4 2 3 Disarming with duress mode p 14 4 2 4 Panic event p 14 4 2 5 System forced arming p 14 5 GSM AND PHONE COMMUNICATIONS P 14 5 1 Calls reception p 14 5 1 1 Remote listening p 14 5 2 Receiving SMS from control u...

Page 24: ...ducts include batteries re chargeable or otherwise as an emergency backup power supply If connected incorrectly they may cause damage to the product or prop erty and may endanger the operator explosion and fire INSTALLER WARNINGS Comply strictly with current standards governing the installation of elec trical systems and security systems and with the manufacturer s direc tions given in the manuals...

Reviews: