13
interval.
To disarm with double confirmation function active:
– Place the proximity key near the sensitive area.
– Go to the nearest keypad within the time set during
system configuration (
Double confirmation time for
duress
).
U
U
U
U
U
U
– Key in user code.
– Press
OK
.
All areas feature a separate timer: if a disarming procedure
involves multiple areas, timers of all involved areas will
activate.
The code entered may not be of the same user that dis-
armed the unit; however each user can lock only timers of
pertaining areas.
If the time interval elapses without the confirmation of the
system disarming, a duress alarm related to the user that
disarmed will be created.
3.2.4 system forced arming
If the option
Activate arming lock
is enabled in Browse-
rOne, system arming will be denied if some fault conditions
occur.
If arming is not allowed because of dialler fault or lack of
supervision events, users can force system arming only us-
ing control devices that control areas involved in the arming
lock.
– When arming can be forced, the red arming LED will start
blinking rapidly.
– Within 15 seconds: to force arming place M4 key again
near the reader or press
OK
on the keypad to which the
reader is connected.
Bypassed detectors will not cause system lock.
4
REMOTE CONTROLs UsAGE
Remote control devices can be used to arm (either totally or
partially) and disarm systems.
Remote controls have to be learned to a specific device.
Remote control
Device
ATLANTE4, ATLANTE6
RIVERRF
ATLANTE4PLUS
RIVERRFPLUS
ATLANTE2K
GATEWAY2K
4.1 Function keys
The following image refers to ATLANTE2K device. Other de-
vices may not feature the same function keys.
A
Key "TOTAL ARMING"
B
Key "TOTAL DISARMING"
C
Key "PARTIAL ARMING 1"
D
Key "PARTIAL ARMING 2"
E
Two-colour LED for data transmission status
1
Key "OUTPUT 1 CONTROL"
2
Key "OUTPUT 2 CONTROL"
A
1
C
D
2
B
E
Please refer to the manual of the remote control in use for
information on keys and LED indications.
4.2 Operation with remote controls
Before proceeding, please see arming general information
(paragraph 2.4.1
p. 5).
4.2.1 system arming
To arm the system, press one of the following keys:
• "Total arming" (A): arms
all sectors authorised
for the
user
• "Partial arming 1" (C): arms
sectors proposed
for the user
• "Partial arming 2" (D): arms
sectors authorised but not
the proposed ones
Example
if sectors authorised are number 1, 2, 3, 4, 5, 6, and pro-
posed ones are 1, 2, 3, 4, only the remaining sectors 5 and
6 will be armed.
For some remote controls, installers can modify the
default configuration of "Partial arming 1" key and
"Partial arming 2" key so that such keys will arm/dis-
arm defined sectors instead of sectors proposed and
sectors authorised but not the proposed ones
respectively