16
6.2 A-B temperatures management
A more advanced temperature control can be realised us-
ing output functions and alarm/pre-alarm thresholds (in
BrowserOne: page
Temperature
, tab
A-B Temperature
management
).
The installer can set four thresholds with corresponding
events: two for high temperature (Pre-alarm A and Alarm A),
and two for low temperature (Pre-alarm B and Alarm B.)
The installer can set an output to activate when the temper-
ature reaches one of the thresholds and to reset when the
temperature falls again within threshold ranges set.
If the temperature is not over/under thresholds set, the out-
put can be reset also by users in the two following ways:
It is required the installer has set one output with
A-B
temperature control
function associated to a
SX
sec-
tor key.
Reset from keypad
– Key in user code.
– Press SX sector key.
Reset via sMs
– Send SMS command
S.X
(see chapter 9
p. 18).
Example
If S3 key has been associated to the function, the output will
reset:
• with the user code keyed in and followed by S3 key, or
• sending an SMS text with
S.3
7
E-CONNECT
e-Connect is a supervision software for EL.MO. intrusion de-
tection systems.
It allows users to control and manage their systems via the
Internet, a PC or a smartphone application.
Operations with e-Connect software:
• check control unit status (anomalies, tamper events,
alarms)
• arm / disarm procedures
• read events log
• enable/disable outputs
For the correct use of the software, units have to be
equipped with one of the following modules:
• MDLAN or MDGSME for PREGIO1000, PREGIO1000BM,
PREGIO2000
• MDWIFIH or MDGSMI for PREGIO500
The installer has to configure the unit suitably and set one
user account.
To access e-Connect, download the app (available for An-
droid, iOS and Windows systems) or login to https://connect.
elmospa.com.
For more details on e-Connect, please see the user manual
on
elmospa.com
site (also for download).
8
MAX sECURITY
Sectors can be armed with
Max Security
property.
Such property can be set by the installer during configuration.
When a sector is armed in Max Security mode it can only be
disabled
• by a user with ‘max security’ property (enabled via Brow-
serOne during configuration)
• via weekly programmer
• by the installer via software.
8.1 Arming with Max security
To arm with Max Security property: