20
no enabled outputs
There are no outputs activated.
9.2.6 Excluded zones report
The control unit replies with SMS texts containing excluded
zones status, one text per each zone pertaining to the user.
Replying SMS
Indication
zone [Zone Name]
EXCLUDED
The zone is excluded.
no zones bypassed
There are no excluded zones.
9.2.7 sectors report
The control unit replies with SMS texts containing areas
arming status, one text per each zone pertaining to the user.
Replying SMS
Indication
[Area Name] ARMED
All area sectors are armed.
[Area Name] DISARMED
All area sectors are disarmed.
[Area Name] S12--
Some sectors of the area are armed.
Numbers indicate sectors armed,
hyphens sectors disarmed.
9.2.8 Temperature report
The control unit replies with an SMS text containing the unit
internal temperature measured by the sensor.
Replying SMS
Indication
+/- XX,X degrees
Temperature detected.
9.3 Replies to command messages
The control unit will reply with one SMS (or more) containing
the response to the command sent.
9.3.1 Arm/disarm commands
The command affects all sectors authorised for the user.
The control unit will reply with one SMS per each area au-
thorised for the user:
Replying SMS
Indication
[Area Name] ARMED
All area sectors are armed.
[Area Name] DISARMED
All area sectors are disarmed.
[Area Name] S 1 2 - -
Some sectors of the area are armed.
Numbers indicate sectors armed,
hyphens sectors disarmed.
A.DENIED
Arming impossible
D.DENIED
Disarming impossible
9.3.2 GsM ON/OFF
Replying SMS
Indication
GSM ON
GSM module on.
GSM TURNING OFF
GSM module is turning off.
G.DENIED
GSM on/off functions disabled or the user
is not authorised for Small Maintenance
9.3.3 Remote listening request
Replying SMS
Indication
REMOTE LISTENING REQ.
Command M.ON recognised.
9.3.4 Activate/deactivate outputs
The control unit will reply with one SMS per output.
Replying SMS
Indication
output [Output Name]
ENABLED
The output is active.
output [Output Name]
DISABLED
The output is not active.
A.DENIED
Output activation is not allowed or
the user is not authorised for Small
Maintenance.
D.DENIED
Output deactivation is not allowed or
the user is not authorised for Small
Maintenance.
9.3.5 Bypass/include zone
The control unit will reply with one SMS per zone.
Replying SMS
Indication
zone [Zone Name]
EXCLUDED
The zone is excluded.
zone [Zone Name] ACTIVE
The zone is active.
E.DENIED
Zone exclusion is not allowed or the user
is not authorised for Small Maintenance.
N.DENIED
Zone inclusion is not allowed or the user
is not authorised for Small Maintenance.
9.3.6 Output commands
Replying SMS
Indication
COMMAND S1 EXECUTED
The command has been executed.
SX
stands for sector keys (S1 to S4). Each sector key manag-
es one output, according to software configuration.
9.3.7 Disable balance reading
Replying SMS
Indication
SIM BALANCE READING
DISABLED
Reading disabled.
SIM BALANCE READING
ENABLED
Reading enabled.
C.DENIED
Reading disabled or the user is not
authorised for Small Maintenance.
Summary of Contents for PREGIO Series