TF 50 HWI
E87 264 01
For maximum safety, please read the safety instructions that are included with each machine. Before using the machine,
please read the instructions.
Note the following information
Serial no:_______________ Date of purchase:________________
The machine is intended for drying and heating buildings where there is a need for temporary heating, drying or air
circulation. The machine shall be connected to an electrical supply protected by a residual current disconnect.
No more than 4 machines on one residual current disconnect (RCD). The machine can be used as a cooler, consult
El-Björn for replacement off water battery.
Machine data
Machine dimensions
H incl. air distributor
2,200 mm
H excl. air distributor
1,310 mm
W
760
mm
D
940 mm
Weight
148 kg
Noise level
70 dB(A)
Motor and air side
Rated voltage
400 V
Power
1.6 kW
Rated current
2.5 A
Electrical connection
3N~400V
Air flow with distributor 3,900 m³/h
Fuse
16A
Water side
Connector Camlock
25 mm
Max water temp. in
80°
Max input water pressure
16 bar
Encapsulation class
IP 44
Thermal power 50 kW at following values:
- Water temp. 80–50°C
- Water flow 0.4 l/s
- Incl. air temp +5°C
EC/EAA declaration of conformity, see
www.elbjorn.com
Product description
The TF 50 HWI machine is built on a aluminium framework
equipped with insulating material on the inside to reduce the
noise level. The heater battery is protected inside the machine
and is connected via 25 mm Camlock couplings. The heat
to the machine is taken from hot water. The TF50 HWI’s air
intake is on the rear.
The air is drawn through the filter and heater battery by the fan
and is then fed up to the air distributor and finally out into the
room through the air distributor vents.
In order to achieve the best drying and heating performance,
the machine should be positioned as centrally in the room as
possible.
It is very important that the fan runs continuously in order to
provide the best drying and heating performance.
1 Filter door
2 Filter
3 Heater battery complete
4 Potentiometer, factory setting 8
5 On/Off switch
6 Thermostat
7 Air distributor
8 Input water
12.
10.
5.
11.
14.
16.
7.
4.
13.
17.
8.
9.
6.
3.
2.
1.
15.
GB
9 Return water
10 Motor protection indicator
11 Frost protection indicator
12 Lifting eye
13 Fan motor
14 CEE 16A Input
15 Drain valve
16 Handle
17 Room sensor