TROUBLESHOOTING
BEFORE PROCEEDING, DEPRESSURIZE THE AIR TANK TO ZERO AND
DISCONNECT THE DEVICE FROM THE MAINS.
The equipment, in particular the cooling fan, must be kept clean to ensure the long-term
efficiency of the cooler
– the cooling fins must be cleaned occasionally to remove any dust.
Troubleshooting can be performed only by qualified personnel.
MALFUNCTIONS
POSSIBLE CAUSE
REMEDY
Compressor does
not start
No voltage at the pressure switch
Check the voltage in the socket
Checking the main switch - turn on
the switch (4) to the “I” position. (Fig.
9)
Loose conductor at terminal
– tighten
Check the electrical cord
– replace
defective cord
Turn on the switch (2) on the pressure
switch (1) (Fig. 9)
Compressor in a cabinet - not
connected to the cabinet by a cord -
create a cord connection from the
cabinet (chap. 14)
Compressor (without a cabinet) which
previously worked in a cabinet - there
is no connection in the terminal strip
(chap. 19.10)
Motor winding failure, damaged
thermal overload protection
Faulty capacitor
Seized piston or other rotating part
Pressure switch does not switch
Replace motor or windings
Replace capacitor
Replace damaged parts
Check the function of the pressure
switch
Cabinet switch does
not switch off the
compressor
There is a compressor in the cabinet
that previously worked separately
(there is a jumper in the compressor
terminal strip)
Remove the jumper from the terminal
strip, see. Chap. 19.11
Compressor often
switches on
Air leak in compressed air
distribution system
Leaking non-return valve
Large volume of condensed liquid in
pressure vessel
Low compressor performance
Check compressed air distribution
system
– seal loose joints
Clean non-return valve, replace
seals, replace non-return valve
Drain condensed liquid
Check the time to fill the air tank
Low pressure in air
tank (compressor
running constantly)
High air usage by device, Leak from
pneumatic distribution system, Low
air pump output
Air pump malfunction
Dryer malfunction
Decrease air consumption
Use compressor with higher capacity
Check pneumatic system
– seal
loose connections
Clean / replace the pump
Clean / replace the pump
Replace dryer
Summary of Contents for DK50-10 S
Page 2: ......
Page 4: ...CONTENTS 5 INHALT 42 TABLES DES MATI RES 81 118 SPIS TRE CI 157 OBSAH 194 OBSAH 231...
Page 19: ...DK50 10 01 2022 19 NP DK50 10 16_01 2022 MD Fig 2 DK50 10Z M Compressor with dryer...
Page 20: ...DK50 10 NP DK50 10 16_01 2022 MD 20 01 2022 Fig 3 Compressor DK50 10 S M 8 10bar...
Page 38: ...DK50 10 NP DK50 10 16_01 2022 MD 38 01 2022 Fig 15 230V B A...
Page 57: ...DK50 10 01 2022 57 NP DK50 10 16_01 2022 MD Abb 2 DK50 10Z M Kompressor mit Trockner...
Page 58: ...DK50 10 NP DK50 10 16_01 2022 MD 58 01 2022 Abb 3 Kompressor DK50 10 S M 8 10bar...
Page 76: ...DK50 10 NP DK50 10 16_01 2022 MD 76 01 2022 Abb 15 230V B A...
Page 95: ...DK50 10 01 2022 95 NP DK50 10 16_01 2022 MD Fig 2 DK50 10Z M Compresseur avec s cheur...
Page 96: ...DK50 10 NP DK50 10 16_01 2022 MD 96 01 2022 Fig 3 Compresseur DK50 10 S M 8 10bar...
Page 114: ...DK50 10 NP DK50 10 16_01 2022 MD 114 01 2022 Fig 15 230V B A...
Page 119: ...DK50 10 01 2022 119 NP DK50 10 16_01 2022 MD 2017 745 EU MDR...
Page 120: ...DK50 10 NP DK50 10 16_01 2022 MD 120 01 2022 CE...
Page 121: ...DK50 10 01 2022 121 NP DK50 10 16_01 2022 MD...
Page 122: ...DK50 10 NP DK50 10 16_01 2022 MD 122 01 2022 25 55 C 24 70 C 90...
Page 133: ...DK50 10 01 2022 133 NP DK50 10 16_01 2022 MD 2 DK50 10Z M DK50 10Z M...
Page 134: ...DK50 10 NP DK50 10 16_01 2022 MD 134 01 2022 3 DK50 10 S M 8 10...
Page 136: ...DK50 10 NP DK50 10 16_01 2022 MD 136 01 2022 7 7 5 C 40 C 70 15 3...
Page 137: ...DK50 10 01 2022 137 NP DK50 10 16_01 2022 MD 4 5 5 4...
Page 138: ...DK50 10 NP DK50 10 16_01 2022 MD 138 01 2022 6 6 1 2 7 7 16 A 2 1 7...
Page 139: ...DK50 10 01 2022 139 NP DK50 10 16_01 2022 MD DK50 10S M 10 4 DK50 10S M 8 10 1 8 1 8 1 2...
Page 148: ...DK50 10 NP DK50 10 16_01 2022 MD 148 01 2022 a e a 40 C B2 40 C EV1 EV2 40 C a...
Page 150: ...DK50 10 NP DK50 10 16_01 2022 MD 150 01 2022 13 2 1 14 1 2 3 4 3 21 14 14 1 4 3 2 13 1 2...
Page 151: ...DK50 10 01 2022 151 NP DK50 10 16_01 2022 MD 15 B 15 15 A B A B 15 B...
Page 152: ...DK50 10 NP DK50 10 16_01 2022 MD 152 01 2022 15 230V B A...
Page 153: ...DK50 10 01 2022 153 NP DK50 10 16_01 2022 MD 15 15 14 1 14 2 15 B A B A 1 2 8 5 9 15 A...
Page 154: ...DK50 10 NP DK50 10 16_01 2022 MD 154 01 2022 I 9 2 1 9 14 19 10...
Page 155: ...DK50 10 01 2022 155 NP DK50 10 16_01 2022 MD a e 7 10 1 9 2 1 8...
Page 156: ...DK50 10 NP DK50 10 16_01 2022 MD 156 01 2022 1 9...
Page 171: ...DK50 10 01 2022 171 NP DK50 10 16_01 2022 MD Rys 2 DK50 10Z M spr arka z osuszaczem...
Page 172: ...DK50 10 NP DK50 10 16_01 2022 MD 172 01 2022 Rys 3 Spr arka DK50 10 S M 8 10 bar w...
Page 190: ...DK50 10 NP DK50 10 16_01 2022 MD 190 01 2022 Rys 15 230V B A...
Page 208: ...DK50 10 NP DK50 10 16_01 2022 MD 208 01 2022 Obr 2 DK50 10Z M Kompresor so su i om...
Page 209: ...DK50 10 01 2022 209 NP DK50 10 16_01 2022 MD Obr 3 Kompresor DK50 10S M 8 10bar...
Page 227: ...DK50 10 01 2022 227 NP DK50 10 16_01 2022 MD Obr 15 230V B A...
Page 245: ...DK50 10 01 2022 245 NP DK50 10 16_01 2022 MD Obr 2 DK50 10Z M Kompresor se su i em...
Page 246: ...DK50 10 NP DK50 10 16_01 2022 MD 246 01 2022 Obr 3 Kompresor DK50 10S M 8 10bar...
Page 264: ...DK50 10 NP DK50 10 16_01 2022 MD 264 01 2022 Obr 15 230V B A...
Page 275: ......