InstructIon manual for:

SUPER QUIET 
COMPRESSORS

thank you for purchasing a sealey product. manufactured to a high standard this product will, if used according to these instructions and  
properly maintained, give you years of trouble free performance.

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. 

USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE 
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.

1.2.  

GENERAL SAFETY INSTRUCTIONS

familiarise yourself with the application and limitations of the compressor.    

Ensure that the compressor is in good order and condition before use. If in any doubt do not use. contact an electrician/service agent.

  WARNING! the compressor must be serviced by an authorised agent only. DO NOT tamper with, or attempt to adjust, the   

 

pressure switch or the safety valve.

Before moving, or maintaining the compressor

 

ensure that it is unplugged from the mains supply and that the air tank pressure has been   

 

vented. 

only use recommended parts and accessories. to use unauthorised items may be dangerous and will invalidate your warranty.

read the instructions regarding any accessory used with the compressor. Ensure that the safe working pressure of any air appliance used  

 

exceeds the output pressure of the compressor.

Ensure that the air supply valve is turned off before disconnecting the air supply hose.

Keep tools and other items away from the compressor when it is in use and keep the area clean and free of unrelated items.

Ensure that the air hose is not tangled, twisted or pinched.

Keep children and unauthorised persons away from the work area.

DO NOT

 dis-assemble compressor for any reason. the unit must be checked by qualified personnel only.

DO NOT

 use the compressor outdoors, or in damp, or wet, locations and 

DO NOT

 operate it within the vicinity of flammable liquids, gases  

 

or solids.

DO NOT

 touch compressor cylinder, cylinder head or pipe from head to tank as will be hot and will remain so for some time after shutdown.

DO NOT

 attempt to move the compressor by pulling the air supply hose. only move the compressor by the handle.

DO NOT

 attempt to lift or move the compressor by any means other than by the handle. 

1.1.  

ELECTRICAL SAFETY

  

WARNING! 

It is the responsibility of the owner and the operator to read, understand and comply with the following:

You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other 
connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. a 
residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We also recommend that a residual current 
Device (rcD) is used. It is particularly important to use an rcD with portable products that are plugged into a supply which is not protected 
by an rccB. If in any doubt consult a qualified electrician. You may obtain a residual current Device by contacting your sealey dealer. 

You must

 also read and understand the following instructions concerning electrical safety.

1.1.1. the 

Electricity at Work Act 1989 

requires all portable electrical appliances, if used on business premises, to be tested by a qualified  

 

electrician, using a Portable appliance tester (Pat), at least once a year.

1.1.2. the 

Health & Safety at Work Act 1974 

makes owners of electrical appliances responsible for the safe condition of those appliances  

 

and the safety of the appliance operators. 

If in any doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and 1.1.2.   
 

and use a Portable appliance tester.

1.1.4.  Ensure that cables are always protected against short circuit and overload.
1.1.5. regularly inspect power supply cables and plugs for wear or damage and check all   
 

connections to ensure that none is loose.

1.1.6. 

Important:

 Ensure that the voltage marked on the appliance matches the power supply to be  

 

used and that the plug is fitted with the correct fuse - see recommended fuse rating at right.

1.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOT 

pull the plug from the socket by the cable.

1.1.9. 

DO NOT

 use worn or damaged cables, plugs or connectors. Immediately have any faulty 

 

item repaired or replaced by a qualified electrician. When an asta/Bs approved uK 

 

3 pin plug is damaged, cut the cable just above the plug and 

dispose of the plug safely. 

 

fit a new plug according to the following instructions (uK only).

 

a)  Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.

 

b)  Connect the BROWN live wire to the live terminal ‘L’.

 

c)  Connect the BLUE neutral wire to the neutral terminal ‘N’.

 

d)  After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer   

 

     insulation extends beyond the cable restraint and that the restraint is tight.

 

Double insulated products, which are always marked with this symbol    , are fitted with live (brown) and neutral (blue) wires only.  

 to rewire, connect the wires as indicated above - 

DO NOT

 connect either wire to the earth terminal.

1.1.10.  Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure  
 

that a 30 amp supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with your  

 

electrician.

1.1.11.  If an extension reel is used it should be fully unwound before connection. a reel with an rcD fitted is preferred since any appliance   
 

plugged into it will be protected. the section of the cores in the cable is important and should be at least 1.5mm², but to be absolutely  

 

sure that the capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we   

 

recommend the use of 2.5mm² section cable. 

1.  SAFETY INSTRUCTIONS

Original Language Version

moDEl no's

SSQC0903P

SSQC2405P

SSQC2409

RECOMMENDED FUSE RATING:

 13 AMP

ssQc0903P, ssQc2405P, ssQc2409    Issue: 3 (sP) -  22/07/13

© Jack sealey limited

Summary of Contents for SSQC0903P

Page 1: ... not protected by an rccB If in any doubt consult a qualified electrician You may obtain a residual current Device by contacting your sealey dealer You must also read and understand the following instructions concerning electrical safety 1 1 1 the Electricity at Work Act 1989 requires all portable electrical appliances if used on business premises to be tested by a qualified electrician using a Po...

Page 2: ... crankcase causing damage to the compressor and possible personal injury 3 6 screw insert air filter fig 1 into inlet port IMPORTANT Take care when selecting tools for use with the compressor Air tool manufacturers normally express the volume of air required to operate a tool in cubic feet per minute cfm This refers to free air delivered by the compressor air out which varies according to the pres...

Page 3: ...e switch box indicates the pressure inside the main tank NOT the pressure supplied to the air equipment which is shown on the gauge attached to the regulator should the pressure in the main tank exceed the pre set maximum pressure the safety valve will activate the safety valve is adjacent to the regulator WARNING For this reason DO NOT tamper with or adjust the switch or the safety valve NOTE Whe...

Page 4: ...og the pump intake filter and may cause internal damage to pump motor components Please note that any parts damaged by any type of contamination will not be covered by warranty 6 MAINTENANCE Maintenance Procedure Once a Week Once a Month Once a Year check the oil level is in the middle of the sight glass add more synthetic compressor oil if needed 4 Drain the water collected in the air outlet filt...

Page 5: ...restart current overload trip has operated remove from main supply and Investigate and remedy reason for overload 5 compressor stops and does not restart motor failure contact authorised service agent 6a compressor does not stop at max pressure Pressure switch fault contact authorised service agent 6B compressor does not stop at max pressure filter clogged Head gasket or valve fault replace filter...