background image

INSTRUCTIONS FOR:

 

COMPRESSOR - 500LTR BELT DRIVE 7.5hp 3ph 

2-STAGE WITH CAST CYLINDERS

MODEL No:

 

SAC55075B

 

Original Language Version

 SAC55075B     Issue: 1 - 24/12/14

 © Jack Sealey Limited

IMPORTANT:

 

PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS.  USE THE PRODUCT 

CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL 

INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.

Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these 

instructions, and properly maintained, give you years of trouble free performance.

Guide to symbols

 

  

Warning: 

Electricity

 

  

Warning: 

Hot Surface

 

  

Warning: 

Automatic  

 

   

start up

 

 

   Wear ear protection

 

  

Read the instruction  

 

  manual before use

 

DO NOT

 open the air    

 

cock before an air hose  

 

is attached

 

  

 

DO NOT

 operate the    

 

compressor with 

 

enclosure displaced  

 

Ensure oil level is 

 

correct before first use

 

  

 

 1.  SAFETY

1.1.   ELECTRICAL SAFETY

 

 

  

WARNING!

 It is the responsibility of the owner and the  

 

   

operator to read, understand and comply with the following: You  

   

must check all electrical products, before use, to ensure that    

   

they are safe. You must inspect power cables, plugs, sockets    

   

and any other connectors for wear or damage. You must ensure  

   

that the risk of electric shock is minimised by the installation of   

   

appropriate safety devices. A Residual Current Circuit Breaker   

   

(RCCB) should be incorporated in the main distribution board.   

   

We also recommend that a Residual Current Device (RCD) is    

   

used. It is particularly important to use an RCD with portable    

   

products that are plugged into a supply which is not protected by  

   

an RCCB. If in any doubt consult a qualified electrician. You may  

   

obtain a Residual Current Device by contacting your Sealey    

   

dealer. You must also read and understand the following  

 

   

instructions concerning electrical safety.

1.1.1. The 

Electricity at Work Act 1989

 requires that all portable  

 

   

electrical appliances, if used on business premises, are tested   

   

by a qualified electrician, using a Portable Appliance Tester  

 

   

(PAT), at least once a year.

1.1.2. The 

Health & Safety at Work Act 1974

 makes owners of  

 

   

electrical appliances responsible for the safe condition of those  

   

appliances and the safety of the appliance operators. 

If in any   

   doubt about electrical safety, contact a qualified electrician.

1.1.3.  Ensure that the insulation on all cables and on the appliance is   

   

safe before connecting it to the power supply. See 1.1.1. and    

   

1.1.2. and use a Portable Appliance Tester.

1.1.4.  Ensure that cables are always protected against short circuit    

   

and overload.

1.1.5.  Regularly inspect power supply cables and plugs for wear or    

   damage and check all connections to ensure that none is loose.

1.1.6. 

Important:

 Ensure that the voltage marked on the appliance    

   

matches the power supply to be used and that the plug is fitted  

   

with the correct fuse (see 1.1.10. below).

1.1.7. 

DO NOT

 pull or carry the appliance by the power cable.

1.1.8. 

DO NOT

 pull the plug from the socket by the cable.

1.1.9. 

DO NOT

 use worn or damaged cables, plugs or connectors.    

   

Immediately have any faulty item repaired or replaced by a  

 

   

qualified electrician.    

 

 WARNING! 

ELECTRICAL INSTALLATION TO  A 3 PHASE    

 

415VOLT SUPPLY MUST ONLY BE CARRIED OUT BY A  

 

 

QUALIFIED ELECTRICIAN.

  

1.1.10  This product must be fitted with a 3 phase plug wired as  

 

 

illustration in (fig.1), wired to an appropriately fused supply.

 

Connect GREEN/YELLOW wire to Earth ‘E’

 

Connect BROWN wire to L1 Terminal.*

 

Connect  BLACK wire to L2 Terminal.*

 

Connect the GREY wire to L3 Terminal.*

 

WARNING!

 

IT IS ESSENTIAL TO OBSERVE PULLEY DIRECTION 

ON INITIAL START UP, SEE fig.2 AND PULLEY GUARD. IF 

INCORRECT, STOP IMMEDIATELY AND CONSULT A QUALIFIED 

ELECTRICIAN TO INVERT 2 PHASES*. 

*NOTE:

 The cable core colours found in the mains cable on this  

 

compressor are consistent with Amendment 2 to 7671:2001. When 

completed, check there are no bare wires, that all wires have been 

connected correctly and the cable restraint is tight. 

1.1.11 

DO NOT

 use this product with an extension cable.

 

  

IMPORTANT USER INFORMATION!

  

 

Over-current protection of the power circuit is required in  

 

 

accordance with 7.2 of EN 60204-1:2006. The supply  

 

 

disconnecting device to be in accordance with 5.3 of 

 

EN 60204-1:2006. Ask a qualified electrician about compliance.

1.2.   GENERAL SAFETY 

3   

Familiarise yourself with the application and limitations of the    

   

compressor.   

 

3   

Ensure the compressor is in good order and condition before    

   

use. If in any doubt do not use the unit and contact an  

 

   

electrician/service agent.

   

WARNING! 

Compressor must only be serviced by an  

 

   

authorised agent. DO NOT tamper with, or attempt to  

 

   

adjust, pressure switch or safety valve.

3   

Before moving, or maintaining the compressor ensure it is  

 

   

unplugged from the mains supply and that the air tank pressure  

   

has been vented. 

3   

Maintain the compressor in good condition and replace any    

   

damaged or worn parts. Use genuine parts only. 

Unauthorised   

   

parts may be dangerous and will invalidate your warranty.

3   

Read the instructions relating to any accessory to be used  

 

   

with this compressor. Ensure the safe working pressure of  

 

   

any air appliance used exceeds compressors output   

 

   

pressure. If using a spray gun, check that the area selected    

   

for spraying is provided with an air change system/ventilation.

3   

Ensure the air supply valve is turned off before disconnecting    

   

the air supply hose.

3   

Use the compressor in a well ventilated area and ensure it is    

   

placed on a firm surface.

fig.1

Summary of Contents for SAC55075B

Page 1: ...erload 1 1 5 Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that none is loose 1 1 6 Important Ensure that the voltage marked on the appliance matches the power supply to be used and that the plug is fitted with the correct fuse see 1 1 10 below 1 1 7 DO NOT pull or carry the appliance by the power cable 1 1 8 DO NOT pull the plug from the so...

Page 2: ...l see section 5 7 for recommended oils We DO NOT recommend using mineral oil in these compressors DO NOT overfill 7 DO NOT operate the compressor without an air filter 7 DO NOT allow anyone to operate the compressor unless they have received full instructions WARNING The air tank is a pressure vessel and the following safety measures apply 7 No welding operations are to be carried out on any press...

Page 3: ...kly 50hrs 100hrs 400 hrs Drain condensation Check oil level Clean intake filter Check for oil leaks Replace oil Check cut out General cleaning of compressor Replace air filter Check tube fittings and electrical connections Original Language Version Jack Sealey Limited SAC55075B Issue 1 24 12 14 5 MAINTENANCE 5 6 Maintenance Schedule 4 3 STARTING THE COMPRESSOR 4 3 1 Check that the ON OFF switch fi...

Page 4: ... is available for this product To obtain a parts listing and or diagram please log on to www sealey co uk email sales sealey co uk or telephone 01284 757500 Environmental Protection Recycle unwanted materials instead of disposing of them as waste All tools accessories and packaging should be sorted taken to a recycle centre and disposed of in a manner which is compatible with the environment WEEE ...

Page 5: ......

Reviews: