PRODUCT MAINTENANCE
NP-DK50-Nx2VTM-ADM-EN-1_06-2022
50
06/2022
Condensate from compressors
with air dryers is automatically
drained into a vessel to collect
condensate.
Monitor the level in the vessel
using the markings (depending
on the volume of the vessel),
and empty at least once a day.
Fig. 16: Check of the condensate collection vessel
22.6. Inlet filter replacement
The filters located in the
compressor air pump enclosure
cover must be replaced at
defined intervals.
Intake filter replacement:
Pull out the rubber plug by hand
(2).
Remove the dirty intake filter (1).
Insert a new filter and replace
the rubber plug.
Pre-filter replacement:
Pull out the pre-filter by hand (3).
Replace with a new one and
insert it back.
Fig. 17: Inlet filter replacement
Summary of Contents for DK 50 4X2VT/M
Page 1: ...DK50 4x2VT M DK50 6x2VT M USER MANUAL EN...
Page 2: ......
Page 13: ...PRODUCT DESCRIPTION 06 2022 13 NP DK50 Nx2VTM ADM EN 1_06 2022 Fig 2 Adsorption dryer...
Page 24: ...INSTALLATION NP DK50 Nx2VTM ADM EN 1_06 2022 24 06 2022 Fig 5 Handling the compressor module...
Page 31: ...INSTALLATION 06 2022 31 NP DK50 Nx2VTM ADM EN 1_06 2022 15 PNEUMATC DIAGRAMS DK50 4x2VT M...
Page 32: ...INSTALLATION NP DK50 Nx2VTM ADM EN 1_06 2022 32 06 2022 DK50 6x2VT M...
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ...NP DK50 Nx2VTM ADM EN 1_06 2022 112000595 0001...