TROUBLESHOOTING
06/2022
53
NP-DK50-Nx2VTM-ADM-EN-1_06-2022
TROUBLESHOOTING
Risk of electric shock.
Before interfering with the
equipment, first disconnect it
from the mains (remove the
power socket).
Working
with
pressurised
pneumatic components poses a
risk of injury.
Before interfering with the
equipment, vent the air tank and
the compressed air system to
zero pressure.
Troubleshooting may only be
performed
by
a
qualified
service technician.
Damage to the safety valve
could cause pressure to rise to
hazardous levels.
Never adjust a safety valve.
Malfunction
Possible cause
Solution
Compressor does not
start
Problem with electrical power source
Main breaker is off
Power loss
Check mains voltage
Loose terminal in switchboard
– tighten
Check the primary power connection -
replace if damaged
Pressure switch failed
Check terminals and operation of the
pressure switch - replace if damaged
Any of the air pumps
does not start up
(indicator is on)
Loss of power to motor
Check mains voltage
Check the function of the contactor, and
thermal relays - replace if damaged
Loose terminals at the motor terminal
strip - tighten or replace if damaged or
broken
Motor winding shorted, damaged /open
thermal protection/ high ambient
temperature
Replace the motor / decrease the
ambient temperature
Seized up piston or other moving
component (mechanical damage to a
moving part)
Replace damaged parts
Controller malfunction
Check controller operation, check to
ensure software is present - replace if
damaged or upload the correct program
RUN/STOP indicator
is not green
Loss of connection between controller
and expansion module
Check connection
– replace if damaged
Power loss
Check mains voltage
Loose terminal in switchboard
– tighten
Check the primary power connection -
replace if damaged
Problem with electrical power source
Main breaker is off
Controller or expansion module
malfunction
Replace failed controller or expansion
module
Air pumps switch
often, even without
demand for air
Air leak in compressed air distribution
system
Check compressed air distribution
system
– seal loose joints
Leaky check valves
Test check vales and clean, or replace
if damaged
Summary of Contents for DK 50 4X2VT/M
Page 1: ...DK50 4x2VT M DK50 6x2VT M USER MANUAL EN...
Page 2: ......
Page 13: ...PRODUCT DESCRIPTION 06 2022 13 NP DK50 Nx2VTM ADM EN 1_06 2022 Fig 2 Adsorption dryer...
Page 24: ...INSTALLATION NP DK50 Nx2VTM ADM EN 1_06 2022 24 06 2022 Fig 5 Handling the compressor module...
Page 31: ...INSTALLATION 06 2022 31 NP DK50 Nx2VTM ADM EN 1_06 2022 15 PNEUMATC DIAGRAMS DK50 4x2VT M...
Page 32: ...INSTALLATION NP DK50 Nx2VTM ADM EN 1_06 2022 32 06 2022 DK50 6x2VT M...
Page 57: ......
Page 58: ......
Page 59: ......
Page 60: ...NP DK50 Nx2VTM ADM EN 1_06 2022 112000595 0001...