![background image](http://html.mh-extra.com/html/efka/ab286a5400/ab286a5400_instruction-manual_2367391007.webp)
EFKA AB286A5400
7
4 Starting Service
Before putting the control into operation, the following must be ensured, checked and/or adjusted:
§
The correct installation of the drive, the position transmitter and accompanying devices, if necessary
§
The correct adjustment of the direction of rotation of the motor
5 Socket Connectors
The drive receives the commands necessary for its operation from a master computer. A socket with an RS485 interface
and further signal lines is provided for that. Moreover, the control has sockets for the connection of the motor, position
transmitter and external actuator.
B2
Socket for position transmitter in the motor
B18
Socket for 180° sensor
B41
Socket for motor power supply
B80
Socket for actuator
B485
Socket for RS485 interface and further signal lines
S1
Jumper for terminating resistor (see chapter
“Activate/Deactivate Terminating Resistor“)
Factory setting: Jumper S1 closed!
R S 4 8 5
KL2342a
B485
S1
B18
180
B2
B41
B2
B18
M
B41
M
B80
EB...