Parameter 06
- Status Byte 3
Bit 0-1
= 00
Stop with pedal in position –1
è
unpositioned (preset)
= 01
Stop with pedal in position –1
è
position 1
= 10
Stop with pedal in position –1
è
position 2
= 11
Stop with pedal in position –1
è
position 3
Bit 2-3
= 00
Stop with pedal in position –2
è
unpositioned (preset)
= 01
Stop with pedal in position –2
è
position 1
= 10
Stop with pedal in position –2
è
position 2
= 11
Stop with pedal in position –2
è
position 3
Bit 4-5
= 00
Stop with pedal in position 0 (neutral)
è
unpositioned (preset)
= 01
Stop with pedal in position 0 (neutral)
è
position 1
= 10
Stop with pedal in position 0 (neutral)
è
position 2
= 11
Stop with pedal in position 0 (neutral)
è
position 3
Bit 6-7
= 00
Stop with pedal in po1
è
unpositioned (preset)
= 01
Stop with pedal in po1
è
position 1
= 10
Stop with pedal in po1
è
position 2
= 11
Stop with pedal in po1
è
position 3
Parameter 08
- Status Byte 3
Bit 0
= 1
Pedal contact A closed
Bit 1
= 1
Pedal contact B closed
Bit 2
= 1
Pedal contact C closed
Bit 3
= 1
Pedal contact D closed
Bit 4
= 1
Pedal in position –2
Bit 5
= 1
Pedal in position –1
Bit 6
= 1
Pedal in off-position
Bit 7
= 1
Pedal pressed forward
Parameter 0A
- Status Byte 3
Bit 0
Reserved
Bit 1
= 1
Counting direction from motor to handwheel inverted
Bit 2-7
Reserved
Parameter 0F
- Interrupt Control Byte
Bit 0
= 1
Receive interrupt line 1 (IRQ1)
Bit 1
= 1
Transmit interrupt line 1
Bit 2
= 1
Receive interrupt line 2 (IRQ2)
Bit 3
= 1
Transmit interrupt line 2
Bit 5/4
= 00
IRQ1 delay with counter 1
(parameter 4C)
= 01
IRQ1 delay with counter 1, then with timer 1
(parameter 4D)
= 10
IRQ1 delay with timer 1, then with counter 1
= 11
IRQ1 delay with timer 1
Bit 7/6
= 00
IRQ2 delay with counter 2
(parameter 4E)
= 01
IRQ2 delay with counter 2, then with timer 2
(parameter 4F)
= 10
IRQ2 delay with timer 2, then with counter 2
= 11
IRQ2 delay with timer 2
The function of the interrupt control is described in chapter
Interrupt Control
!
Summary of Contents for AB286A5400