Pin number
Signal
Polarity
Use
8
0 V Control Reference
-
0 V reference for ALL control and status
signals listed within this table.
9
Analogue Speed – Control
Input
-
0-10 V Analogue Input
0 V = 0% Speed;
+ 10 V = 100% Speed
10
Chassis / Screen
-
Screen
11
+ 10 V Analogue
Reference – Control
Output
Positive
+ 10 V analogue voltage reference output:
5 mA; uni-polar output, diode protected.
This signal line is not suitable for
connection to cables longer than 30 m.
12
Chassis / Screen
-
Screen
13
Not Connected
-
Unused control pin.
14
REMOTE – Control Input
-
Connect to Pin 2 (0 V) to enable remote
control via Parallel or Serial control modes.
15
NORMAL – Status output
-
Logic LOW when the pump rotational
speed is at normal speed or above.
3.9 Valve connector socket
The pump has a 4-way valve connector socket on the front of the motor controller.
The connector is intended to control a valve. The connector is shown in
connector showing pin numbers on page 27
, with the polarity of the pins marked when
the valve is energised.
The valve connector output is regulated to 24 V d.c. to control the valve and is protected
against overload and short circuits. If the valve load current exceeds the value in
Valve connector technical data on page 26
, the output will shut down to protect the
motor controller.
Table 17
Valve connector technical data
Description
Data
Connector plug
Phoenix part number SACC-DSI-M 8FS-4CON-M12/0.5
Voltage output
24 V d.c. -25%, +10% (18 V d.c. to 26.4 V d.c.)
Current output
500 mA
Page 26
A65901880_D - Technical data
Summary of Contents for nRVi
Page 1: ...Rotary Vane Pumps nRVi INSTRUCTION MANUAL A65901880_D Original instructions edwardsvacuum com...
Page 6: ...This page has been intentionally left blank...
Page 97: ...Page 93 A65901880_D Service...
Page 98: ...This page has been intentionally left blank...
Page 99: ...This page has been intentionally left blank...
Page 100: ...edwardsvacuum com...