![Edwards nRVi Instruction Manual Download Page 27](http://html1.mh-extra.com/html/edwards/nrvi/nrvi_instruction-manual_2366141027.webp)
▪
PEEK (Polyether Ether Ketone)
▪
Viton
▪
Glass
3.5 Noise and vibration data
Note:
The sound level in the final installation should be checked by the user.
Table 11
Noise and vibration data
Parameter
Value
Unit
Sound pressure
*
54.5
dB (A)
Vibration severity
§
Class 1C
* Measured at ultimate vacuum 1 metre from the end of the pump to ISO 11201, High
Vacuum mode .
§ Measured at the inlet port to ISO 2372 (1974).
3.6 Lubrication data
Note:
Safety Data sheets for the rotary pump oils are available on request.
Table 12
Lubrication data
Parameter
Value
Units
nRV14i
nRV6i
nRV10i
nRV14i
Recommended oil
*
Hydrocarbonprepared
pumps
Edwards Ultragrade 19
PFPE-prepared pumps
Krytox 1506 or Fomblin 06/6
Oil capacity
Maximum
0.70
0.70
0.75
1.00
Litres
Minimum
0.42
0.42
0.45
0.65
Litres
* To operate the pump when the ambient temperature is outside the limits specified in
Table: Operating and storage conditions on page 16
, or to optimise the pump
performance when pumping condensable vapours, a different oil may be needed.
3.7 Electrical data
Note:
Use of fuses with the maximum rating specified in
Table: Recommended fuses on page
The nRVi pump controller includes an integrated 10 A fuse which is not replaceable.
Page 23
A65901880_D - Technical data
Summary of Contents for nRVi
Page 1: ...Rotary Vane Pumps nRVi INSTRUCTION MANUAL A65901880_D Original instructions edwardsvacuum com...
Page 6: ...This page has been intentionally left blank...
Page 97: ...Page 93 A65901880_D Service...
Page 98: ...This page has been intentionally left blank...
Page 99: ...This page has been intentionally left blank...
Page 100: ...edwardsvacuum com...