Object
name
Command
Parameter
range
Factory
setting
Data type
Units
Comments
1
-
Decimal
-
Use standby speed
Identification
?S0
-
-
-
-
Acts as wildcard object
number to identify
instrument. Reply
identical to ?S801
Node
?S800
!S800
0..98
0
Decimal
Slave
Address
Multi-drop address
(RS485)
0 = disable multi- drop
mode;
Pump type
?S801
[1..8]
-
String
ASCII
Characters
Pump type (nRVi )
[1..11]
-
String
ASCII
Characters
Motor Control Software
Version number
(Dxxxxxxxx Y) (where
Dxxxxxxxx is the
drawing number and Y
is the revision)
1..255
-
String
Hz
Design frequency (=
Nominal mechanical
frequency of the pump)
Pump
control
!C802
0
-
Decimal
-
Stop the pump
1
-
Decimal
Start the pump
?V802
0..255
-
Decimal
Hz
Reported motor
frequency
64-bits
encoded as
four 16-bit
words:
-
Hexadecimal
-
System status:
<0000..FFFF>;
System status register
1;
<0000..FFFF>;
System status register
2;
<0000..FFFF>;
Warning register and
Fault register
<0000..FFFF>
Speed
control
!C803
0
-
Decimal
-
Use full speed
1
-
Decimal
Use standby speed
Normal
speed
threshold
?S804
!S804
65..100
65
Decimal
%
Normal speed status
output trigger level:
Percentage (%) of
selected speed
Page 29
A65901880_D - Technical data
Summary of Contents for nRVi
Page 1: ...Rotary Vane Pumps nRVi INSTRUCTION MANUAL A65901880_D Original instructions edwardsvacuum com...
Page 6: ...This page has been intentionally left blank...
Page 97: ...Page 93 A65901880_D Service...
Page 98: ...This page has been intentionally left blank...
Page 99: ...This page has been intentionally left blank...
Page 100: ...edwardsvacuum com...