Multi-drop mode can be disabled by assigning the pump an address 0. To do this, send
the command that follows (where dd shows the multi-drop address of the pump. XX
shows the address of the node that is sending the command):
Command
#
d
d
:
x
x
!
S
8
0
0
sp 0
cr
The reply will be as follows:
Reply
#
x
x
:
d
d
*
S
8
0
0
sp 0
cr
When the multi-drop mode is disabled, the pump will not respond to multi-drop
commands. Once multi
‑
drop mode is disabled, the pump will no longer respond to
multi-drop commands.
5.2 Configure the pump using a TIC
The pump can be configured using the TIC Turbo and Instrument Controller or TIC Turbo
Controller.
It is possible to set the following parameters of the pump using the TIC:
▪
Standby speed setting
▪
Normal speed setting
▪
Factory default settings
For information on how to perform these settings, refer to the TIC Turbo and Instrument
controller or TIC Turbo Controller Instruction Manuals.
Note:
It is not possible to configure the analogue output options using the TIC. There is also no
facility within the TIC to assign a multi-drop address to the pump.
Page 51
A65901880_D - Configuration
Summary of Contents for nRVi
Page 1: ...Rotary Vane Pumps nRVi INSTRUCTION MANUAL A65901880_D Original instructions edwardsvacuum com...
Page 6: ...This page has been intentionally left blank...
Page 97: ...Page 93 A65901880_D Service...
Page 98: ...This page has been intentionally left blank...
Page 99: ...This page has been intentionally left blank...
Page 100: ...edwardsvacuum com...