![Edwards nRVi Instruction Manual Download Page 36](http://html1.mh-extra.com/html/edwards/nrvi/nrvi_instruction-manual_2366141036.webp)
Object
name
Command
Parameter
range
Factory
setting
Data type
Units
Comments
<0000..FFFF>;
<0000..FFFF>
register 02; warning
register 01 and fault
register 01
Fault history
4
?V819
0..99999 64-
bits encoded
as four 16-bit
words:
<0000..FFFF>;
<0000..FFFF>;
<0000..FFFF>;
<0000..FFFF>
-
Decimal
Hexidecimal
Hours
Fault history at 4th last
trip:
pump controller
powered time (hours)
system status register
01; system status
register 02; warning
register 01 and fault
register 01
Customer
interface
software
version
?S820
[1..11]
-
String
ASCII
Characters
Customer interface
software version
number (Dxxxxxxxx Y)
(where Dxxxxxxxx is the
drawing number and Y
is the revision)
Factory
settings
!C821
1
-
Decimal
-
Reset all configuration
options and parameters
to factory settings
Motor
control boot
loader
version
?S822
[1..11]
-
String
ASCII
Characters
Motor control boot
loader version number
(Dxxxxxxxx Y) (where
Dxxxxxxxx is the
drawing number and Y
is the revision)
Customer
interface
boot loader
version
?S823
[1..11]
-
String
ASCII
Characters
Customer interface
bootloader version
number (Dxxxxxxxx Y)
(where Dxxxxxxxxis the
drawing number and Y
is the revision)
Service
setting
!S825
?S825
0..3
0
Decimal
-
0: Service indication on
Service LED
1: Service indication on
Service LED and FAIL
line
2: No service indication
on Service LED or FAIL
line
3: Service indication on
FAIL line
Service
status
?V826
One 16-bit
word:
<0000..FFFF>
-
Hexidecimal
-
Service status word -
refer to
Page 32
A65901880_D - Technical data
Summary of Contents for nRVi
Page 1: ...Rotary Vane Pumps nRVi INSTRUCTION MANUAL A65901880_D Original instructions edwardsvacuum com...
Page 6: ...This page has been intentionally left blank...
Page 97: ...Page 93 A65901880_D Service...
Page 98: ...This page has been intentionally left blank...
Page 99: ...This page has been intentionally left blank...
Page 100: ...edwardsvacuum com...