D13510840D - Interface description
Page 82
:PROTection
protecting functions
:CONTaminatio
n
contamination protect
:CONTLimit
contamination limit
:EVACtime
maximum evacuation time
(0 – infinite)
:EVAC2time
maximum evacuation time until 100
mbar (0 - infinite)
:PMAX
maximum pressure in sniff
:PMIN
minimum pressure in sniff
:UNIT
:LR
leak rate unit (ATM*CC/S, G/A,
MBAR*L/S, OZ/YR, PA*M3/S, PPM,
TORR*L/S, SFT3/YR)
:Pressure
pressure unit (ATM, MBAR, PA,
TORR)
:MINVOLume
minimum volume
:PLCINlink
:1_1
Digital in control pin 1
:1_2
Digital in control pin 2
:1_3
Digital in control pin 3
:2_1
Digital in control 2 pin 1
:2_2
Digital in control 2 pin 2
:2_3
Digital in control 2 pin 3
:PLCOUTlink
:5_6_7
Digital out control pin 5,6&7
:8_9_10
Digital out control pin 8,9&10
:11_12_13
Digital out control pin 11,12&13
:14_15_16
Digital out control 2 pin 14,15&16
:PURGe
purge/gas ballast (on, off)
:SAMPLErate
sample rate of digital inputs [s]
:SUPPRession
background suppression (OFF,
INTERN, INLET)
:VACRANGE
vacuum range (NORMAL,
FINE_ONLY,
GROSS_ONLY,GROSS_ONLY_ 920Hz,
PARTIAL_FLOW, PRECISION)
:VOLume
volume
:VENTdelay
vent delay (0, 1, 1.5, 2, NO)
Summary of Contents for ELD500 Series
Page 9: ...D13510840D Contents Page vii...
Page 10: ...This page has been intentionally left blank D13510840D Contents Page viii...
Page 12: ...D13510840D Introduction Page 2 This page has been intentionally left blank...
Page 38: ...D13510840D Page 28 This page has been intentionally left blank...
Page 58: ...D13510840D SL Sniffer line Page 48 This page has been intentionally left blank...
Page 64: ...D13510840D Partial flow adaptor Page 54 This page has been intentionally left blank...
Page 78: ...D13510840D Calibrated leak He 4 6 Page 68 This page has been intentionally left blank...
Page 84: ...D13510840D Calibrated leak screwed socket Page 74 This page has been intentionally left blank...
Page 121: ......