67
5.7.7
Control Panel Message of “Conductivity LO”-
This indication is shown when the conductivity value is below the lower alarm limits as set in
the Set Up screens. This is normally an indication that a problem with the blow down or filter
back wash system has occurred. Please verify the operation of the blow down valves and filter
back wash functions. This message could also be shown if low load conditions with the water
system are occurring (as in winter) if the load to the system is too low, the conductivity of the
water system may not cycle up to the appropriate COC levels. This message may continue until
the load increases on the water system. Monitor the system routinely to verify that this
condition is associated with the load.