Rev. 1.12.11
9.3
Button/switch functions
Key
Description
Fig. 9.3
Master switch (on/off switch)
Fig. 9.4
MENU/EXIT function for entering and exiting the menu levels
(Keep the buttons pressed together)
Increase settings
Decrease settings
Fig. 9.5
Start the pump
Stop the pump
ENTER key to confirm set values
Fig. 9.6
Test function (continuous operation)
9.4
Display indicators
Display
Description
Signal to indicate that the pump is running; the indicator
in the top right of the display goes
through a complete cycle with every stroke of the pump. The letter in the display stands for the
active metering mode setting
(s = standard, m = medium; l = low, v = variable, see chapter
Metering mode
”)
Display of the current metering frequency or rate setting in %
Level signal present (flashing display = level pre-warning, display visible continuously = empty
signal), see chapter
Installation of the suction pipe
Configuration of the
level contact
”.
Metering lock enabled, see chapter
Installation of the metering lock
“
Configuration / Metering lock
”.
Malfunction present, see chapter
”
Fault signals
”.
Internal
Operating mode Internal, see chapter
Operating mode / Internal
”
xxx /min Operating mode Internal, strokes/ min indication
Selection
”
xx %
Operating mode Internal, display in %
x.xx l/h
Operating mode Internal, l/h indication
Pulse
Operating mode Pulse, see chapter
Operating mode / Pulse
”
x..xx mA Operating mode Current, x – xx mA, see chapter
Operating mode / Current
”
Batch
Operating mode Batch, see chapter
Configuration / Batch
”
OFF
Pump is in OFF mode (must be switched on), see chapter
Displays
”
V60+
Dongle box connected, see chapter
Upgrading to
V60
PLUS
”
V60++
Dongle box and OGM
PLUS
Installation of oval gear meter
” or chapter
Configuration / Oval gear meter
”.
Pulse memory enabled, the icon appears as soon as the pulse memory has been enabled in the
configuration; if the icon is flashing, the pump processes the saved pulses immediately, see chapter
Configuration / Pulse memory
”.
c!
Please perform a calibration! This icon appears when metering mode (see chapter
Metering
mode
”) or the maximum metering capacity (see chapter
Configuration / Max. metering
capacity
”) if the pump has been re-adjusted, which means that calibration is imperative in order to
adapt the displays and conversion principles accordingly. The icon disappears after automatic
calibration has been performed, see chapter
Calibration
”
Calibration performed correctly
Alarm
Fault signals
”
Summary of Contents for 417102214
Page 60: ...417102214_EDPL_V60 docx 60 Rev 1 12 11 14 7 3 F rderleistung Typ 06700 0 4 MPa 4 bar Abb 14 5...
Page 61: ...417102214_EDPL_V60 docx 61 Rev 1 12 11 15 Konformit tserkl rung...
Page 121: ...417102214_EDPL_V60 docx 121 Rev 1 12 11 15 Declaration of conformity...
Page 180: ...417102214_EDPL_V60 docx 180 Rev 1 12 11 14 7 3 D bit type 06700 0 4 MPa 4 bar Fig 14 5...
Page 181: ...417102214_EDPL_V60 docx 181 Rev 1 12 11 15 D claration de conformit...