417102214_EDPL_V60.docx
107
Rev. 1.12.11
11.1.3 Gear oil change
CAUTION
The safety regulations of the German Water Resources Law (WHG), as well as all
instructions given in the product specification sheet of the gear oil have to be observed.
Wear appropriate protective clothing.
Fig. 11.4
Pos.
Description
1
Gear bleeder screw
2
Oil-level gauge glass
3
Sealing plug
NOTE
Before changing the oil, the pump has to
be put into operation in order to achieve
a minimum temperature of approx. 30°C.
Draining gear oil:
Manually unscrew gear bleeder screw (pos.
1
).
Place a suitable collecting basin (min. 0.9 l)
underneath the sealing plug (pos.
3
).
Loosen sealing nut with a socket wrench fitting
(SW 19) and unscrew it carefully.
Let the running out oil drain off into the collecting basin.
Screw in the sealing plug with a new O-ring (NBR
∅
9 x 2 mm) and tighten it.
Gear oil top up:
Fill new gear oil into the aperture for the gear bleeder screw (pos.
1
) using an appropriate
funnel (filling volume approx. 0.8 l).
Check the oil level on oil-level gauge glass (pos.
2
); (min. and max. oil level, see Fig. 11.6,
and rectify if necessary.
NOTE
The gear oil must be changed after a maximum of 10.000 hours in operation or every two
years. The gear oil used here is a polyglycol oil of type Klübersynth GH6-320. Only this
gear oil or a polyglycol oil of an identical specification (conforming to DIN ISO 6743) may
be used.
Used gear oil must be disposed of correctly!
Summary of Contents for 417102214
Page 60: ...417102214_EDPL_V60 docx 60 Rev 1 12 11 14 7 3 F rderleistung Typ 06700 0 4 MPa 4 bar Abb 14 5...
Page 61: ...417102214_EDPL_V60 docx 61 Rev 1 12 11 15 Konformit tserkl rung...
Page 121: ...417102214_EDPL_V60 docx 121 Rev 1 12 11 15 Declaration of conformity...
Page 180: ...417102214_EDPL_V60 docx 180 Rev 1 12 11 14 7 3 D bit type 06700 0 4 MPa 4 bar Fig 14 5...
Page 181: ...417102214_EDPL_V60 docx 181 Rev 1 12 11 15 D claration de conformit...