417102214_EDPL_V60.docx
94
Rev. 1.12.11
10.4.7 Configuration / Auto start
This function determines whether the pump is set to 'OFF' when the mains connection is re-
established following a power cut or if the pump should immediately recommence functioning
in the configured operating mode.
10.4.7.1 Selection
Fig. 10.28
-
Auto start is inactive.
The pump goes to 'OFF' when the
mains voltage is connected.
(Default setting)
Auto start is active.
When the mains voltage is connected,
the pump starts functioning in the
configured operating mode.
10.4.8 Configuration / Metering lock
If the metering lock is enabled, the pump only functions if an external enable contact is
connected to plug II between PINs
3
+
4
Installation of activation via a
metering lock
”) regardless of which operating mode is set.
10.4.8.1 Selection
Fig. 10.29
-
Metering lock query inactive.
(Default setting)
Metering lock query active.
10.4.9 Configuration / Level contact
This function specifies whether an open or a closed contact at the level input (plug I, see
chapter
Pin configuration for slot I (3-pin) - Input for level pre-warning and empty
signal
”) is regarded as level OK.
10.4.9.1 Selection
Fig. 10.30
= Contact open:
Level not OK (empty)
Contact closed:
Level OK (full)
(Default setting)
= Contact closed:
Level not OK (empty)
Contact open:
Level OK (full)
Summary of Contents for 417102214
Page 60: ...417102214_EDPL_V60 docx 60 Rev 1 12 11 14 7 3 F rderleistung Typ 06700 0 4 MPa 4 bar Abb 14 5...
Page 61: ...417102214_EDPL_V60 docx 61 Rev 1 12 11 15 Konformit tserkl rung...
Page 121: ...417102214_EDPL_V60 docx 121 Rev 1 12 11 15 Declaration of conformity...
Page 180: ...417102214_EDPL_V60 docx 180 Rev 1 12 11 14 7 3 D bit type 06700 0 4 MPa 4 bar Fig 14 5...
Page 181: ...417102214_EDPL_V60 docx 181 Rev 1 12 11 15 D claration de conformit...