417102214_EDPL_V60.docx
76
Rev. 1.12.11
7.2.5
Pin configuration on terminal strip X1
Fig. 7.20
Terminal
Wire colour
(Connection cable)
Pin assignment
1
Brown
Level pre-warning input
2
Blue
Level empty signal input
3
Black
GND (ground)
4
Batch metering input
5
Output 5 V,DC (load max. 100 mA)
6
Pulse activation input
7
GND (ground)
8
Metering lock input
9
Input for standard signal 0/4..20 mA (+)
10
Input for standard signal 0/4..20 mA (–)
11
Stroke signal output (+)
12
Stroke signal output (–)
7.2.5.1
Pin configuration for slot I (3-pin) - Input for level pre-warning and empty signal
Fig. 7.21
Terminal
assignment
X1
PIN
assignment
Connector
Wire colour
(Cable)
Assignment
1
1
Brown
Level pre-warning
input
2
3
Blue
Level empty signal
input
3
4
Black
GND (
┴
)
Connector PIN assignment,
see chapter
Technical specifications
”
7.2.5.1.1 Installation of the suction pipe with a level pre-warning and empty signal
NOTE
Slot I must be occupied at all times, either by the mounted jumpers (protection cap with an
appropriate symbol, see chapter
, Fig. 5.3, pos.
11
) or by connecting the empty signal
device. Level pre-warning active (invertible switching logic, see chapter
“Configuration / Low Level Contact”.
Fig. 7.22
1
+
4
(Connector PIN assignment)
= Level pre-warning input
Level pre-warning switching contact open:
empty signal symbol in display flashes, pump keeps
running.
PIN
Assignment
1
Level pre-warning switch input
4
GND (
┴
)
3
+
4
(Connector PIN assignment) = Level empty signal input,
switch contact level
empty signal open:
empty signal symbol is shown in the display, pump is
locked.
PIN
Assignment
3
Level empty signal switch input
4
GND (
┴
)
Summary of Contents for 417102214
Page 60: ...417102214_EDPL_V60 docx 60 Rev 1 12 11 14 7 3 F rderleistung Typ 06700 0 4 MPa 4 bar Abb 14 5...
Page 61: ...417102214_EDPL_V60 docx 61 Rev 1 12 11 15 Konformit tserkl rung...
Page 121: ...417102214_EDPL_V60 docx 121 Rev 1 12 11 15 Declaration of conformity...
Page 180: ...417102214_EDPL_V60 docx 180 Rev 1 12 11 14 7 3 D bit type 06700 0 4 MPa 4 bar Fig 14 5...
Page 181: ...417102214_EDPL_V60 docx 181 Rev 1 12 11 15 D claration de conformit...