Hydraulic installation
CAUTION!
When connecting the suction and pressure lines, make sure that the
O-rings (Fig. 10, pos. 5 and pos. 11) are installed on the connections to
obtain the necessary sealing effect.
We recommend that you use a suction lance from our product range.
linktarget
[417101964 11 Verschleiß-, Ersatzteile und Zubehör] doesn't exist but @y.link.required='true'
.
Fig. 10: Hydraulic installation
1
Complete metering line
2
O-ring pressure side (metering)
3
Pressure valve
4
Bleed screw
5
Metering head
6
Bleed connection
7
Ventilation hose (not in the scope of the delivery)
8
Suction valve
9
O-ring, suction-side
10 Tapered part
11 Clamping part
12 Union nut
13 Metering hose
Connection for the metering line
During pipe installation:
1.
Place the O-ring (Fig. 10, pos. 2) in the valve groove.
2.
Connect the prefabricated metering line to the output of the metering pump and to
the metering valve.
Installation
30
417101964 Rev. 4-04.2019