14
Opening The Power Supply (refer Sketch 5 on Page 12)
Always de-energize power supply circuit before opening power supply.
To open power supply remove the 2 screws which hold removable panel in place. Rem ove the panel
and loosen the single screw inside the recess.
The front panel of the power supply can now be
removed by a) pulling bottom of fr ont panel out (towards you), then b) slide the front pa nel down (so
front of front of top panel slides out from under top panel).
When opened, the front cover of the power supply should be supported, so as not to put any strain on
internal wiring, by connecting the front cover to the left hand side panel of the power supply, using the
clip provided (refer Sketch 5).
When replacing the front pane l, be sure that all internal wiring is clear of the side and bottom panels,
to allow proper seating of the front panel. Insert sides of front panel into the slots at each side, slide
the front panel UP so its top edge slides under the top panel. When the front panel is in plac e, re-
tighten screw and replace cover plate.
Connecting ‘Cell’ to Power Supply
The ‘Cell’ connecting lead is factory-attached to t he power supply, with connectors at the end of the
lead for attachment to ‘Cell’ head. Fit the BLACK c onnectors to eit her titanium rod. Ensure the
connection is snug. The BLUE Flow Sensor should be pushed onto the threaded shaft of the small
bolt.
Connecting a Chemistry Controller (ORP) to Power Supply
Plugging the ECO-matic directly into a Chemistry Controller will void the E CO-matic warranty. This
connection must be done through a lo w voltage switch which is an optional item available through
your dealer when ordering your ECO-matic unit.