5
Important Safety Instructions
1. “WARNING: To reduce the risk of injury, do not permit children to operate this device.”
2. “WARNING: heavy pool (or spa) usage, and higher temperatures may require higher chlorine
output to maintain proper free available chlorine residuals.”
3. “If additional chlorine is required due to heavy bather loads, use sodium hypochlorite (liquid
chlorine) to maintain an appropriate chlorine residual in the water.”
4. “Maintaining high salt and chlorine levels above recommended range can contribute to
corrosion of pool or spa equipment.”
5. “DO NOT add pool or spa chemicals directly to the skimmer. This may damage the cell.”
6. “Check the expiry date of the test kit as test results may be inaccurate if used after that date.”
7. “The life expectancy of the electrolytic cell is 8700 hours under normal use conditions.”
8. “When replacing the cell, only use replacement cells having a label that clearly states that it is
a replacement cell for the chlorine generating device ECO-matic MEMS36USA Automatic
Chlorine Generator, REGISTRATION NUMBER 30295,
PEST CONTROL PRODUCTS ACT
.”
9. “Follow all aspects of the local and National Electrical Code(s) when installing ECO-matic
MEMS36USA Automatic Chlorine Generator
10. “NOTE: For outdoor pools, chlorine residuals can be protected from destruction by sun light by
addition of stabilizer (cyanuric acid).
11. “For proper sanitation, spas must be completely drained periodically. The number of days
between COMPLETE SPA DRAINAGE is equal to the volume of spa water in litres, divided by
10 times the maximum number of daily spa users. Refill spa with water and repeat
DIRECTIONS FOR USE of the device.”
12. Do not use this device with bromide products
Health and Hyperthermia warnings for spas:
1.
“People with a medical condition should consult a physician before entering pool or spa water.”
2.
“Maximum spa water usage temperature is 40°C. Bathing in spa water at 40°C should not
exceed 15 minutes.”
3.
When installing and using this
electrical equipm ent, basic safety precaut ions should always be
followed, including the following:
1. READ AND FOLLOW ALL INSTRUCTIONS
2. A green colored terminal or a terminal mark ed G, GR, Ground, Grounding, or the international
ground symbol is located inside the power control box (‘power s upply’). To reduce the risk o f
electric shock, this terminal must be connected to the grounding means pr ovided in the electric
supply panel with a continuous c opper wire equivalent in size to the circuit conductors supplying
this equipment.
Summary of Contents for MEMS36USA
Page 12: ...12 offs on back of power supply provide ventilation for wall mounted units...
Page 15: ...15...
Page 16: ...16 Electrical Connection...
Page 31: ...30...