Indicators - What They Mean
Output readings on the DIGITAL DISPLAY can fall due to any (or combination of) the following: cooler
water temperatures, warming of power supply (in heated equipment rooms for example), lower th an
normal power voltage, lower salt levels, scaling occurring on ‘Cell’.
Provided LED 1 and LED 2 are both GREEN ( and t he ‘Cell’ is not scaling excessively), your ECO-
matic is performing (producing) satisfactorily.
Indicator
Display LED1
LED2
What's
Happening
STAND-BY ON
Blank
Green
Green
1. Unit is in start-up mode
2. "Cell" is OFF cycle during normal operation
(refer System Control)
3. System Control set at MIN.
FLOW ON
Blank
Green
Green
1. Insufficient flow through "Cell"
(Gas or air at Stand-By on "Cell", check
pump/pipes for damage, leaks)
2. Gas Sensor lead not connected to "Cell"
3. System is wired incorrectly.
Approx
Green
Green
System operating normally.
90-100
Approx
Green
Red
1. "Cell" is dirty, scale build up.
90-100
Clean cell
2.
Water Temperature Cold. Switch to Winter Mode
3.
Salt level below min. Add salt
4. "Cell" failing. Test and/or replace "cell"
Varying Red
Red
Unit preparing to Cut-Out. (See low Salinity
Indicator and cut out).
1.
'Cell" is dirty, scale build up. Clean cell
2.
Water Temperature Cold. Switch to Winter Mode
3.
Salt level below min. Add salt
4. "Cell" failing. Test and/or replace "cell"
STAND-BY ON
Blank
Red
Red
System protection activated. Unit has Cut-Out.
Follow above procedures.
WINTER MODE ON
Approx
Green
Green
System operating normally - in Winter Mode.
75-85
Only operate in Winter mode if water is very cold.
Red LED(s): scaled "Cell" or low salt level.
Operation