20.1.2
M
OUNTING THE BURNER DOOR
IMPORTANT:
Before mounting the burner door, make sure that its
gaskets and insulation are in excellent shape.
If any signs of damage or ageing are present, these
parts must be replaced.
The burner door must be mounted back on the heat
exchanger as follows:
- Place the burner door with its holes over the six
threaded studs.
Careful! When handling too rough or misplacing
the holes over the threaded studs, the burner door
insulation and/or gaskets can be damaged.
Ensure that the door is well positioned with respect
to the threaded studs, before pushing it onto the
exchanger.
- Keep the burner door firmly in place by pushing the
gas/air premix manifold with one hand at the mid-
dle at point A.
- Hand tighten the flange nuts with the other hand as
far as possible onto the threaded studs.
Now the burner door is in place and the nuts can be
tightened with a torque wrench.
-
Tighten the nuts in the order given in the pic-
ture
-
The specified torque value for tightening the
burner door flange nuts is
8 Nm
Tighten in given order.
torque value = 8 Nm
Instructions for the user.
After installing and commissioning of the water heater, demonstrate the operation of the entire water heating sys-
tem to the end-user. The user should be made familiar with all safety precautions of the water heater and the
installation. The user should be instructed that service and maintenance of the water heater is required every
twelve months. Regular service and maintenance is essential for a safe and proper operation of the water heater.
Hand over the documents supplied with the water heater.
A
Summary of Contents for CB 105 HW
Page 69: ...E93 1803 901 HW 70 12 6 Electrical schematic...
Page 70: ...E93 1803 901 HW 71...
Page 71: ...E93 1803 901 HW 72 12 7 Ladder Logic Diagram LOW MAINS VOLTAGE VOLTAGE...
Page 127: ...E93 1803 901 HW 128 22 SPARE PARTS CB 85 HW CB 105 HW and CB 125 HW exploded view...
Page 128: ...E93 1803 901 HW 129...
Page 129: ...E93 1803 901 HW 130 CB 155 HW exploded view...
Page 130: ...E93 1803 901 HW 131...
Page 145: ......
Page 146: ......