E93.1803.901 HW
122
Fiber braid replacement
If the high temp braided rope is damaged and needs to be changed, it has to be replaced by new braids using the
method described below.
The high temp braided rope is maintained by silicone glue.
- Remove electrodes.
- Remove the braids by sliding under the periphery
a thin tool to loosen the braids and remove it.
- Remove and clean the residues of the braids and
silicone glue.
- Put a thin string of glue silicone temperature-re-
sistant in the seal housing. (Loctite 5366 or Ottoseal
S17)
- Engage the high temp braided rope and place it
in contact of the glue and press the braids.
- Reinstall electrodes