Default values and settings
Default
Minimum
Maximum
Pump type – Boiler controlled pump
Energy-efficient
-
-
Boiler control temperature
70 °C
70 °C
90 °C
Switch off temperature
76 °C
76 °C
95 °C
Outdoor sensor min power
8 °C
7 °C
25 °C
Outdoor sensor max power
2 °C
-10 °C
6 °C
Boiler power rating
16/20/25/32
10/21 kW
20/32 kW
PWM pump
70 %
30 %
100 %
DHW set temperature
50 °C
30 °C
75 °C
DHW hysteresis
15 °C
5 °C
20 °C
Accumulator set temperature
30 °C
30 °C
75 °C
Accumulator hysteresis
5
5
20
Pump on temp (accumulator mode)
40 °C
10 °C
80 °C
14 Default values and settings
93