Setting DHW priority.
During the hot water times, the heating circuits are
only switched on when no hot water is demanded.
Setting DHW hysteresis.
The DHW hysteresis can be set between 5K and 20
K.
Setting the time programm of the DHW.
By pressing the start and stoptime appear.
Activate the times with
During the activated time, the boiler regulates to
the values indicated by the hot water sensor.
The hot water control is not activated outside the
set times!
Display current accumulator temperature.
74
13 Controller for heating circuits and DHW
Installation Manual