Display current accumulator temperature.
Setting the accumulator set temperature.
Note:
The accumulator set temperature can be set in the
range of 30° C to 75° C.
Setting hysteresis Accumulator set temperature
The accumulator hysteresis can bet set between 5
K and 20 K.
The boiler switches on when the difference of the
set temperature is higher than adjusted.
Setting pump release temperature of the heating
circuit.
The pump release temperature can be set between
10° C and 80° C. If the temperature is too low, the
DHW reserve outside the DHW time program may
be limited.
86
13 Controller for heating circuits and DHW
Installation Manual