Designation of plug-in posi-
tion
Voltage
Name of sensors, motors and pumps
Z25 (BSK)
1 2 3 4 5 6
24 Volt
Flame return gate (Belimo)
Z16 (UW)
13 PE N
230 Volt
DHW pump/ Accumulator pump
Z17 (HK)
N PE 14
230 Volt
Only active if a sensor is connected to terminal 43/44.
Z18 (ZUEND)
N PE 22
230 Volt
Ignition
Z19 (ES)
2 3 N PE
6
230 Volt
Burner motor
Z34 (SZ)
17 PE N
230 Volt
Flue gas fan
Z33 (RM)
15 PE N
230 Volt
Motor boiler cleaning device
Z35 (LUFT)
N PE 11
230 Volt
Burner fan
Z36 (STB)
17 PE 19
230 Volt
Safety temperature sensor
Z10 (NETZ)
L PE N
230 Volt
Power supply boiler control unit
Z38
(AOUT PWM 1)
16 17
24 Volt
PWM signal for room thermostat Z26 or BR1
Z39
3 4
24 Volt
PWM pump signal for output of room thermostat Z27
Z40
5 6
24 Volt
PWM pump signal for output of room thermostat Z28
Z37 (PF)
1 2
24 Volt
Accumulator sensor
Z24 (FRT)
13 12
24 Volt
Combustion chamber sensor
Z23 (UP)
4 3 2
24 Volt
Negative draft measuring
Z22 (KF)
9 8
24 Volt
Boiler sensor
Z21 (AF)
41 42
24 Volt
Outdoor sensor
Z20 (WW)
43 44
24 Volt
DHW sensor
Z32
35 36
24 Volt
Not used
Z30
15 16
24 Volt
Pilot switch for hopper
Z28
3 4 5
24 Volt
Room thermostat Z40
Z27
24 25 26
24 Volt
Room thermostat Z39
Z26 (BR1)
8 7
24 Volt
Burner contact - Room thermostat Z38
JMP
-
-
Jumper for speed controlled high-efficiency pump
10.2
Cable routing
Reroute cables after dismantling the casing or other system components.
10 Fuses - boiler controller
31
Installation Manual