13.4.1
Commissioning controller version C
After code input:
Display of the current boiler temperature
Setting the boiler set temperature.
The boiler set temperature can be set in the range
of 70 ° C to 90 ° C if a higher boiler temperature
requirement or a larger modulation range is
required.
Setting of the boiler switch off temperature.
When the boiler switch off temperature is reached,
the boiler switches off.
Note:
A too high switch off temperature.can cause the
safety temperature limiter to release.