Pressing the
Enter
key accepts the location of the marker on the first anomaly and proceeds to the next anomaly
marker listed. Automatically, the program displays the dashed marker in the vicinity of the location of the second
anomaly echo which is now highlight in green.
The
Skip Marker
button is used to pass over any downhole anomaly listed in the table but that is presently below
the liquid level or that does not generate a clear echo signal, such as plugged perforations. Any changes made
must be saved using the
Enter
key.
Skip Marker
will
ignore
any changes made and proceed to the next marker.
If a marker is accidentally skipped, the operator must press the
Skip Marker
key through each selected marker
until the highlighted selection comes back around to the marker in question.
Note that the Acoustic Velocity (
AV
) is now recomputed based on the new Round Trip Travel Time (
RTTT
) of
5.061 seconds yielding a value of 1094 feet per seconds for the average
AV
between the wellhead and the first
gas lift mandrel.