Acquisition of Acoustic Records
– Model H Quick Reference
1 - Power up instrument by pressing the ON/OFF button on the instrument panel.
2 - Press the soft key corresponding to “Continue” and select “Accept” at the Conditions of
Operation.
3-To continue with Acquisition press the soft key below the Acquire Data label.
4- Use the Star Keys Up and Down buttons to select the group that contains the information
for the well being tested.
5- Use the Star Keys Right Arrow to select the Well option to display the list of wells included
in the chosen Group.
6- Use the Star Keys Up and Down arrows to select the desired well from the list.
7- Press the “Acquire Shot” button on the instrument panel after the well has been selected
from the list (either pressing the button below the “Select Well” label or the “Enter” button of
the 5 button Star Keys)
8- Select the method of acquisition, “Implosion” or “Explosion,” and review the check list
displayed for connection and preparation of the hardware to perform the acoustic test.
9 – When ready press the button under the “Continue” label and monitor the noise signal
strength to determine the level of differential pressure that should be used.
10 – Press the “Start” button after adjusting the gas gun pressure if necessary.
11 – Actuate the gas gun control (trigger) to generate the pulse.
12 – Press the button under the Stop label to terminate acquisition after observing the liquid
level response and a repeat if desired.
13- Save or Discard the acquired shot.
14- Return to Main Menu or Retest the same well.