EPX400-A20CU – Manual
Page 10 / 62
R2, T2
Connection to the phone
RING, TIP
Terminals for a PSTN telephone
PGND
Ground line for protecting an external phone line
Antenna
Connector for external LTE / UMTS antenna
NOTES:
OUT1 and OUT2 outputs can sink up to 100mA. Don’t short this outputs to
power supply because it can cause permanent damage of the output.
Don’t connect power supply when LTE antenna isn’t connected, because it
can cause permanent damage of LTE/3G modem.
3.3.
WIRED CONNECTIONS OF CONTROL PANEL WITH
COMMUNICATOR EPX400-A20CU
Figure 3. Wired connections of control panel with communicator EPX400-A20CU.
Legend:
PGM
—
IN1 (Armed Status)
COM
—
GND (Ground)
COM
—
NC3
Zone
—
C3 (Keyswitch Arm)
RING
—
R1
TIP
—
T1
This connection makes it possible to manage (remote arm /
disarm) the control panel using communicator EPX400-A20CU
and a mobile application EBS Security. To do this you need to
create connection between output and input according to the
wiring (in EBS Config 2.0 and EBS Security – see below)
This connection allows receive events from the control panel to the
communicator and send them to the Monitoring Station via Ethernet or
GPRS. It also provide downloading features (remote configuration).