automatic system start-up. If you have a SIM card without PIN code protection, you
can enter any value, e.g. 0000.
If the PIN you enter is incorrect, SIM card may be blocked after you insert the card
and power on the communicator. To unblock the SIM card you will need to enter the
PUK code (using any smartphone) before you can use the card again.
Factory PIN number in EPX400-A20CU is set to 1111.
6.4.
CONFIGURE ETHERNET
Server parameters
6.4.1.
In this section define the server parameters in the monitoring station.
Server address
6.4.1.1.
This is the IP address of the monitoring system receiver (OSM.Server), e.g.
“89.123.115.8”. The address can be specified as a domain name of the server, e.g.
“module.gprs.com”.
For domain name addresses, a DNS sever address is also required.
Server port
6.4.1.2.
Specifies the server port assigned to receive data from the communicator.
Ethernet parameters
6.4.2.
In this section define the Ethernet parameters needed for wired connection.
Define IP address settings. By default, it is set as DHCP (Dynamic Host Configuration
Protocol).
DHCP
is a protocol which dynamically assigns an IP address to each
computer, complete with TCP/IP configuration parameters. It is possible to change it
to static IP. After checking
Static
you should fill up additional fields: