![EBS EPX PRO Installation And Programming Manual Download Page 16](http://html1.mh-extra.com/html/ebs/epx-pro/epx-pro_installation-and-programming-manual_3804170016.webp)
EPX400-A20CU – Manual
Page 16 / 62
Server address
6.3.1.1.
This is the IP address of the monitoring system receiver (OSM.Server), e.g.
“89.123.115.8”. The address can be specified as a domain name of the server, e.g.
“module.gprs.com”.
For domain name addresses, a DNS sever address is also required.
Server port
6.3.1.2.
Specifies the server port assigned to receive data from the communicator.
APN parameters
6.3.2.
In this section we define the APN parameters needed for LTE/HSPA+ connection.
APN
6.3.2.1.
In “APN” field you can enter the APN name. This parameter depends on the
LTE/UMTS network provider whose services you are going to use. It specifies the
name of the access point to the LTE/HSPA+ network. It is possible to use a private
access point. In this case, the name of the access point will be provided by your GSM
network provider.
This is usually not required with public APNs.
User ID
6.3.2.2.
In this field you can enter the user name required to connect to the LTE/HSPA+
network. This is usually not required with public APNs. If you have a private APN, you
should ask your provider for this parameter.
Note: Using a private APN increases the security of the system.
User password
6.3.2.3.
In this field you can enter the user password required to connect to the LTE/HSPA+
network. This is usually not required with public APNs. If you have a private APN, you
should ask your provider for this parameter.
Note: Using a private APN increases the security of the system.
Primary / Secondary DNS
6.3.2.4.
Identifies the address of the primary / secondary DNS server (Domain Name
System). If you provided the server's address as a domain, at least one DNS address
must be specified.
Access
6.3.3.
In this section we define the parameters of access to the device.
Service code
6.3.3.1.
Protects the device against unauthorized access. It is used during the device
programming process and for remote control of the device (in TCP/IP or SMS mode).
The code is factory set to
1111
. You should change this code at the first
programming the device. It may contain up to seven alphanumeric characters.
SIM card PIN
6.3.3.2.
As the device works in a LTE/UMTS network, you need a SIM card from a mobile
telephone network provider. Before first use, you need to enter the PIN code of the
SIM card that will be used with the particular communicator. This is required for