Pr11 – Offset Addition 1 [-999.999 to 999.999in] or [-9999.99 to
9999.99mm]
When offset 1 is selected (see section 4 – Offset Addition),
this value is added to the current ABS position. Default:
2.000IN
Only active if Pr10 is set to 1.
Note: Default is set in inches
Pr12 – Offset Addition 2 [-999.999 to 999.999in] or [-9999.99 to
9999.99mm]
When offset 2 is selected (see section 4 –
Offset Addition
), this value
is added to the current ABS position. Default: 1.500IN
Only active if Pr 10 is set to 1.
Note: Default is set in inches
Pr13 – Offset Addition 3 [-999.999 to 999.999in] or [-9999.99 to
9999.99mm]
When offset 3 is selected (see section 4 –
Offset Addition
), this value
is added to the current ABS position and displayed. Default: 1.500IN
Only active if Pr 10 is set to 1.
Note: Default is set in inches
Pr14 – Output Signal Mode
[0, 1]
Configures the hardware output signal for activation on MONitor drift
Conditions or Upper/Lower limit alarm conditions. (24VDC displays
only)
0 = Monitor Drift,
1 = Limit Alarm
SEE ALSO Pr15, Pr16, Pr17
Pr15 – Output Polarity
[0, 1]
Used to configure the signal output. N/O or N/C in relation to circuit
ground.
0 = N/O, the output is Normally Open (not conducting to ground).
1 = N/C, the output is Normally Closed (conducting to ground).
Pr16 – Lower Limit [-999.999 to 999.999in] or [-9999.99 to 9999.99mm]
Sets the lower limit alarm value. Default = 0.000IN.
Active only when parameter Pr14 = 1. Note: Default is set in inches
Pr17 – Upper Limit [-999.999 to 999.999in] or [-9999.99 to 9999.99mm]
Sets the upper limit alarm value. Default = 5.000IN.
Active only when parameter Pr14 = 1. Note: Default is set in inches