Pr18 – Drift Tolerance [.01 to 9999.99mm] or [.001 to 999.999in].
Range of motion allowed (+ or -) while in Monitor mode.
Default = .01IN. Note: Default is set in Inches
Pr19 – Automatic Monitor ON Time [0, 1 or 2]
Configures display to automatically activate Monitor mode after 30
or 60 seconds of encoder inactivity.
0 = disabled. 1 = 30 seconds. 2 = 60 seconds.
Pr20 – Automatic Monitor OFF Enable [0, 1]
Configures display to automatically exit Monitor mode after a
Programmed distance (Pr21) has been exceeded from the drift
Tolerance
position
(Pr18).
0 = disabled. 1 = enabled.
Pr21 – Automatic Monitor OFF Distance [0.001 to 999.999in] or
[0.01 to 9999.99mm].
The distance that must be exceeded from the drift tolerance
Position (Pr18) to activate auto monitor off. Default = 0.500in
This parameter is relevant only when Pr20=1. Note: Default set in
Inches
Pr22 – Backlight ON time [0, 1, 2, 3 or 4]
The ON time of the LCD backlighting (24VDC displays only).
0 = always off. 1 = 3 seconds. 2 = 7 seconds. 3 = 15 seconds.
4 = always on.
Backlighting is activated when a key is pressed.
Pr23 – Future Enhancement DO NOT CHANGE [0, 1, 2] Default=1
Pr24 – Future Enhancement DO NOT CHANGE [0...63] Default=0
Pr25 – Future Enhancement DO NOT CHANGE [0...31] Default=0
CAUTION: Pressing and holding the ON/OFF and MODE key for 10 seconds while
the display is turned off will perform a full segment LCD test AND re-set all
programming parameters to factory defaults
REV A 12-2-05 23