32
Temperature, A and B
The thermostat uses external sensors that can be installed as
A
or
B
. If
there are two sensors installed, it is possible to switch between
A
,
B
or
A & B
.
Moisture sensor, C
The thermostat uses moisture sensor C together with temperature sensor
A.
Delay
+HEATING
The delay can be set to ensure that the entire installation is free of snow
and ice before the thermostat is switched off. When the moisture sensor no
longer detects moisture, the thermostat will remain active for the set time,
before it switches off. The need for delay varies depending on the installation
and the location of the sensor.
A delay of up to four hours can be set, in intervals of 30 minutes. The factory
setting is zero.
Reset
RESET
There are three choices under the reset menu:
CONN TIME
,
OP MODE
and
FAC
SET
. The
RESET
menu is under
SYSTEM
in the
MAIN MENU
.
Reset connection time
CONN TIME
The connection time is shown in hours; as with a vehicle trip meter, it shows
the number of hours an installation has been connected for since it was last
reset. This is beneficial if you want to calculate the energy consumption for
a certain period. The thermostat also has a counter that cannot be reset,
which shows the total hours the installation has been connected for.
To see the total and momentary connection times, press when the thermo-
stat is in display mode.
The reset function is in the
SYSTEM
menu under
RESET
; from here, select
CONN TIME
. This is preset to
NO
and is changed to
YES
by pressing and
confirming with .
Reset the operation mode settings
OP MODE
Settings can be reset in
OP MODE MAX/MIN
. All programs are reset and the
temperature and sensor settings return to the output values. Resetting does
not affect the choice of
OP MODE
,
LANGUAGE
or setting for
DATE/TIME
.
The reset function is in the
SYSTEM
menu under
RESET
, and there select
CONN
TIME
. This is preset to
NO
and is changed to
YES
by pressing and confirm-
ing with .