35
Voltage
230 VAC +/- 10 % ~ 50 Hz
Break-off capacity
3680 W/16 A/230 VAC
Power consumption
2.5 W
Application range
-20 °C to +150 °C divided into two ranges
Low temperature range
-20 °C to +75 °C – Sensor type NTC
High temperature range 0 °C to +150 °C – Sensor type PTC
Roof sensor, moisture
24 VDC, NO
Connection cable
max 2.5mm²
Loading cos
φ
= 1
Connection difference
Adju/- 0.3 to 10.3 °C
Encapsulation class
IP20
Reserve power
50 hours
Max length, sensor cable 50 m, 2x1.5 mm²
Alarm relay
2 A/120 VAC Normal connection
Installation
Standard DIN-rail EN 50022-35
Ambient temperature
-20 °C to +45 °C
Technical data
Unit dimensions drawing
Certification:
EMC/2500
VAC RoHS WEEE CB
10
18
21
21
35
90
70
63.
5
Test value for NTC sensor
Test value for PTC sensor
-10 °C
42.5 k
Ω
0 °C
27.3 k
Ω
+10 °C
18.0 k
Ω
+20 °C
12.1 k
Ω
+25 °C
10.0 k
Ω
+70 °C
1392
Ω
+90 °C
1591
Ω
+110 °C
1805
Ω
+130 °C
2023
Ω
+150 °C
2211
Ω