ST-670

 

HDS Infrared Thermometer

Instruction

 

 Manual

RoHS

COMPLIANT

Summary of Contents for ST-670

Page 1: ...Infrared Thermometer TE E R M H O D M S R I E N H F T R A D R E ST 670 HDSInfraredThermometer Instruction Manual RoHS COMPLIANT ...

Page 2: ......

Page 3: ...HDS Infrared Thermometer Instruction Manual Version 01 07 MAY RoHS COMPLIANT ...

Page 4: ...ions 4 Operation Instructions Unit Diagram Function 5 Techniques of Infrared Thermometer 6 Maintenance 1 1 Features 2 1 Cautions 4 1 Quick Start 4 2 4 3 Operation 4 4 C F Laser Switch and Batter Change 5 1 Field of view FOV ratio 5 2 Emissivity Table Content 1 2 4 5 1 1 2 2 5 5 7 9 10 10 11 11 ...

Page 5: ...rd temperature and high DS ratio These allow user to monitor the target temperature for a long distance far away from the potential risk High DS ratio Adjustable emissivity from 0 1 to 1 00 in 0 01 steps Ultra low power consumption in shutdown mode Extended long time measuring reliability Laser sighting On Off is switchable Backlit LCD display C or F selectable Electronic trigger lock 1 2 Applicat...

Page 6: ...ng Note D o n o t p o i n t l a s e r d i r e c t l y a t e y e U s e c a u t i o n a r o u n d r e f l e c t i v e s u r f a c e s K e e p o u t o f r e a c h o f c h i l d r e n 2 1 Cautions DO NOT submerge the unit in water This product is not designed for use in medical evaluations The product can only be used to measure body temperature simply for reference They are meant for industrial and s...

Page 7: ...nt may not meet its stated accuracy Dangerous refer to this manual before using the meter CE Certification The device may not be disposed of with the trash It promotes the re use recycling and other forms of recovery of used materials and components and to improve the environmental performance of all operators manufacturers traders treatment facilities involved in the life cycle of products Dispos...

Page 8: ...lution 0 1ºC 0 1 F Response Time 500 ms Emissivity Adjustable 0 1 1 0 Distance Spot Ratio 30 1 Supply Voltage 9V Auto Power Off Automaticall after approx 6 s y Operating Temp 0 50 32 122 10 90 RH C F Switchable YES Backlight YES Laser Sight Switchable YES Max Min Avg YES 10 Point Memory YES Audio Alarm YES Auto Measuring YES Dual Display YES Tripod Mount YES Dimensions 200x166x51 mm Weight 280g Ap...

Page 9: ... point the unit at the target pull the trigger and hold Be sure to consider the target area inside the angle of vision of this instrument The single spot of laser is used for aiming only 4 2 Unit diagram 5 Measuring Trigger Display Screen Laser Sighting Battery and Cover Control Panel ...

Page 10: ...13 14 15 SCAN HOLD AUTO C F Indication Main Temperature Display Max Min Avg Set Record Value Lock Key Mode Key Up Button Laser Buzzer On Off Battery Low Data Log ΔT Emissivity High Low Alarm Memory Key Down Button 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 ...

Page 11: ...splay the temperature during measurement The maximum temperature within one shot measuring The minimum temperature within one shot measuring The average temperature within one shot measuring The highest and lowest temperature difference within one shot measuring Recall the stored data by using or button Emissivity for more accuracy on different materials Highest alarm temperature setting Lowest al...

Page 12: ... functions can be activated always in any step of operations mode in flow chart d In SCAN mode the LCD displays both the current tempera ture in Celsius or Fahrenheit The unit will HOLD the last reading for 30 seconds after the trigger is released When the battery is low the battery icon is display but the unit will continue to function e While DATA flashes on the left bottom the value on the main...

Page 13: ...eplace the battery when the battery voltage drops below the voltage for reliable operation and at the same time the low battery symbol will appear To change the 9V battery pull open the unit s handle under the trigger After replacing the battery push back and snap in place C F Switch Laser on off 9V Battery Battery cover release button ...

Page 14: ...strument operates and is determined by the optics of the unit The FOV is the ratio of the distance from the target to the target diameter The smaller the target the closer you should be to it When the target diameter is small it is important to bring the thermome ter closer to the targetto insure that only the target is measured excluding the surroundings ...

Page 15: ... to measure moving and intermittent targets targets in a vacuum and targets that inaccessible due to hostile environments geometry limitations or safety hazard The cost is relatively high although in some cases is comparable to contact devices Emissivity is the ability of an object to emit or absorb energy Perfect emitters have an emissivity of 1 emitting 100 of incident energy An object with an e...

Page 16: ... rolled polished w lines 21 70 0 04 Iron galvanized bright 0 13 Iron plate completely 20 68 0 69 Rolled sheet steel 21 71 0 66 Oxidized iron 100 212 0 74 Wrought iron 21 70 0 94 Molten iron 1299 1399 3270 2550 0 29 Copper polished 21 117 70 242 0 02 Copper scraped shiny not mirrored 22 72 0 07 Copper Plate heavily oxidized 25 77 0 78 Enamel white fused on iron 19 66 0 9 Formica 27 81 0 94 Frozen s...

Page 17: ......

Page 18: ...ST 670 Version 01 07 MAY 3F No 122 Sec 1 Sanmin Road Ban Ciao Taipei 220 Taiwan R O C TEL 886 2 2956 8198 FAX 886 2 2956 7662 http www sentrytek com tw PA05 0000670 01 ...