background image

2/12

Emergency On Call Service: Local representative (

Eaton.eu/aftersales

) or +49 (0) 180 5 223822 (de, en)

05

/19

IL

04716

025Z

M22-XPV…

…K10

…K01

M22-ST-X

…K20

…K11

…K02

M22-XPV60-Y-24

M22-XPV60-Y-120

M22-XPV60-Y-230

M = 1.2 - 2 Nm

(M = 10.6 - 17.7 lb-in)

1

2

M22-MS

13

14

21

22

M22-XZK…

M22-XYK…

M22-I…

M22-E…

C22-PV…

50

mm

(1.97”)

13

14

23

24

13

14

21

22

11

12

21

22

4 x 0.34 mm

2

AWG22

8 mm

(0.31”)

M = 0.8 Nm

M = 7.08 lb-in

2 x 0.75 - 1.5 mm

2

AWG18 - AWG16

2 x 0.75 - 1.5 mm

2

AWG18 - AWG16

2 x 0.75 - 1.5 mm

2

AWG18 - AWG16

60/75 °C Cu wire only

a

b

3.2 mm

±0.2

(0.13")

±0.01

24.1

mm

(0.95

")

+0.02

0

22.3 mm

(0.88")

1 - 6 mm

(0.04 - 0.24

")

+0.4

0

+0.016

0

+0.4

0

mm

in

a ≧

b ≧

a ≧

b ≧

C22-PV…45…

55

55

2.17

2.17

C22-PV…60…

70

70

2.76

2.76

M22-XPV60-Y-…

70

70

2.76

2.76

22.3 mm

(0.88“)

22

mm

-0.4

24.1

mm

(0.95“)

(0.87“)

-0.02

60/80 mm

(2.36“/3.15”)

10 mm

+0.2

(0.39“)

+0.01

3.2 mm

(0.13“)

11

5

9

2

6

10

3

7

11

4

12

8

24 V AC/DC

≦ 20 mA

0 V

0

1

3

2

4

3

2

1

8

7

6

5

12

11

10

9

120

V

AC

230

V

AC

F

20 mA

Summary of Contents for RMQ-Titan C22-PV Series

Page 1: ...ido a corrente eléctrica Apenas electricistas e pessoas com formação electrotécnica podem executar os trabalhos que a seguir se descrevem Livsfara genom elektrisk ström Endast utbildade elektriker och personer som undervisats i elektroteknik får utföra de arbeten som beskrivs nedan Hengenvaarallinen jännite Vain pätevät sähköasentajat ja opastusta saaneet henkilöt saavat suorittaa seuraavat työt N...

Page 2: ...mm2 AWG22 8 mm 0 31 M 0 8 Nm M 7 08 lb in 2 x 0 75 1 5 mm2 AWG18 AWG16 2 x 0 75 1 5 mm2 AWG18 AWG16 2 x 0 75 1 5 mm2 AWG18 AWG16 60 75 C Cu wire only a b 3 2 mm 0 2 0 13 0 01 24 1 mm 0 95 0 02 0 22 3 mm 0 88 1 6 mm 0 04 0 24 0 4 0 0 016 0 0 4 0 mm in a b a b C22 PV 45 55 55 2 17 2 17 C22 PV 60 70 70 2 76 2 76 M22 XPV60 Y 70 70 2 76 2 76 22 3 mm 0 88 22 mm 0 4 24 1 mm 0 95 0 87 0 02 60 80 mm 2 36 3...

Page 3: ...00 V 415 V 4 A 500 V 2 A Ie DC 13 24 V 3 A 3 A 3 A 42 V 1 7 A 60 V 1 2 A 1 A 1 A 110 V 0 6 A 0 6 A 0 6 A 220 V 0 3 A 0 3 A 0 3 A Ue AC 500 V 230 V 230 V Ue DC 220 V 220 V 220 V Ui 500 V 250 V 250 V Uimp 6000 V AC 4000 V AC 4000 V AC Iq 1 kA 1 kA 1 kA max Kurzschlussschutzeinrichtung schmelzsicherungslos PKZM0 10 FAZ B6 1 gG gL 10 A 10 A 10 A IP 20 20 67 69K 66 67 69K Caractéristiques techniques M2...

Page 4: ...cizia ad es trucioli sabbia ecc In caso di collegamento a cascata di dispositivi di arresto d emergenza si riduce il Performance Level secondo DIN EN 13849 1 a causa di un ridotto riconoscimento dei guasti E7 Se si utilizzano applicazioni di ARRESTO D EMERGENZA in linea di massima C6è necessaria una convalida dell intero impianto secondo EN ISO 13849 2 Verificare il fissaggio meccanico del disposi...

Page 5: ... van de totale installatie conform EN ISO 13849 2 noodzakelijk NOODSTOP inrichting op goede mechanische bevestiging controleren Kabelaansluitingen ontroleren op beschadigingen 115 V 6 A 6 A 2 A 220 V 230 V 240 V 6 A 6 A 1 5 A 380 V 400 V 415 V 4 A 500 V 2 A Ie DC 13 24 V 3 A 3 A 3 A 42 V 1 7 A 60 V 1 2 A 1 A 1 A 110 V 0 6 A 0 6 A 0 6 A 220 V 0 3 A 0 3 A 0 3 A Ue AC 500 V 230 V 230 V Ue DC 220 V 22...

Page 6: ...forme EN ISO 13849 2 Verificar se os dispositivos de desligamento de emergência estão na posição mecânica correta Verificar a integridade das conexões do circuito derivado 115 V 6 A 6 A 2 A 220 V 230 V 240 V 6 A 6 A 1 5 A 380 V 400 V 415 V 4 A 500 V 2 A Ie DC 13 24 V 3 A 3 A 3 A 42 V 1 7 A 60 V 1 2 A 1 A 1 A 110 V 0 6 A 0 6 A 0 6 A 220 V 0 3 A 0 3 A 0 3 A Ue AC 500 V 230 V 230 V Ue DC 220 V 220 V ...

Page 7: ...240 V 6 A 6 A 1 5 A 380 V 400 V 415 V 4 A 500 V 2 A Ie DC 13 24 V 3 A 3 A 3 A 42 V 1 7 A 60 V 1 2 A 1 A 1 A 110 V 0 6 A 0 6 A 0 6 A 220 V 0 3 A 0 3 A 0 3 A Ue AC 500 V 230 V 230 V Ue DC 220 V 220 V 220 V Ui 500 V 250 V 250 V Uimp 6000 V AC 4000 V AC 4000 V AC Iq 1 kA 1 kA 1 kA max zařízení ochrany proti zkratu bez tavné pojistky PKZM0 10 FAZ B6 1 gG gL 10 A 10 A 10 A IP 20 20 67 69K 66 67 69K Tehn...

Page 8: ...pējās iekārtas pārbaude saskaņā ar EN ISO 13849 2 Pārbaudiet vai ārkārtas izslēgšanas mehānisms ir mehāniski nofiksēts Pārbaudiet vai vadu pieslēgumi ir noslēgti 115 V 6 A 6 A 2 A 220 V 230 V 240 V 6 A 6 A 1 5 A 380 V 400 V 415 V 4 A 500 V 2 A Ie DC 13 24 V 3 A 3 A 3 A 42 V 1 7 A 60 V 1 2 A 1 A 1 A 110 V 0 6 A 0 6 A 0 6 A 220 V 0 3 A 0 3 A 0 3 A Ue AC 500 V 230 V 230 V Ue DC 220 V 220 V 220 V Ui 5...

Page 9: ...li na dobro mehansko pritrditev Preveritepriključkevodnikov na poškodbe 115 V 6 A 6 A 2 A 220 V 230 V 240 V 6 A 6 A 1 5 A 380 V 400 V 415 V 4 A 500 V 2 A Ie DC 13 24 V 3 A 3 A 3 A 42 V 1 7 A 60 V 1 2 A 1 A 1 A 110 V 0 6 A 0 6 A 0 6 A 220 V 0 3 A 0 3 A 0 3 A Ue AC 500 V 230 V 230 V Ue DC 220 V 220 V 220 V Ui 500 V 250 V 250 V Uimp 6000 V AC 4000 V AC 4000 V AC Iq 1 kA 1 kA 1 kA maks nastavitev napr...

Page 10: ... privire la poziția mecanică fixă Verificați integritatea racordurilor de cablu 115 V 6 A 6 A 2 A 220 V 230 V 240 V 6 A 6 A 1 5 A 380 V 400 V 415 V 4 A 500 V 2 A Ie DC 13 24 V 3 A 3 A 3 A 42 V 1 7 A 60 V 1 2 A 1 A 1 A 110 V 0 6 A 0 6 A 0 6 A 220 V 0 3 A 0 3 A 0 3 A Ue AC 500 V 230 V 230 V Ue DC 220 V 220 V 220 V Ui 500 V 250 V 250 V Uimp 6000 V AC 4000 V AC 4000 V AC Iq 1 kA 1 kA 1 kA Dispozitiv d...

Page 11: ...bijo za funkcije USTAVITEV V SILI IZKLOP V SILI Definicija funkcij risb ki jih je treba upora biti je določena v sledečih standardih IEC 60204 1 DIN EN 60204 1 ISO 13850 DIN EN ISO 13850 ali v ustreznih nacionalnih standardih AVVISO Gli apparecchi possono essere utilizzati per le funzioni di SPEGNIMENTO ARRESTO DI EMERGENZA La definizione delle funzioni delle icone utilizzate è conte nuta nelle se...

Page 12: ...F G A G A E YA B BE EX A EF F G A E6 L FF NI HJ L a f e L LFF J ML LNI H NIL 3 L FeJL Y B A EF 4E G A E BE EGB AG DA E6 O K F AE M ZLT K F A 4 EG A A A A T LEA SI E E S1 R 8S T T ME W 1EA EQ CE Q AR R OFC A E A EG 3 A W K F A 4 EG A A A A T 9RP R P 7 AR R N E LE F D 4 F G JA E I CE E I GBA E 5 E A DGUV Test Prüf und Zertifizierungsstelle Elektrotechnik Gustav Heinemann Ufer 130 50968 Köln W3 R K H...