Page 31
Chapter 5: Installer Menu Map
Important
: Where noted below the defaults listed enable the control unit to comply with
EN50131 requirements. If you change those settings, the installation may no longer
comply. If the control unit does not comply with EN50131, you must remove any labelling
that indicates compliance.
Some options are not always visible as the relevant hardware is not fitted, or not
applicable to the control unit type.
MENU Option
Factory Default
Notes
1 Detectors/Devices
Detectors
Add/Del Detectors
Exp. R1-nn
Visible only if a radio expander is on
the bus.
Zone nnn...
Delete all
Panel
Zone nnn...
Delete all
Delete all
Program Zones
Zone 000...
Name
“Zone nnn”
Type
Not used
Partitions
None
Visible only in a partitioned system and
when zones have a type other than
“Not Used”.
Attributes
All "off", except Supervision
Visible when zone is given a type other
than “Not Used”.
Some attributes are only available on
particular zone types.
Double Knock does not comply with
EN51031.
Masking must be enabled in System
Options.
Resistance
2k2/4k7
Address Bus
Device
Wired
Expanders
Address Bus Device
Edit Expander
Expander W1-01...
Name
“Exp. W1-nn”
Partitions
Partition 1
Visible only in a partitioned system.
Wired zone type
FSL 2k2/4k7
Loudspeaker volume
Zero when expander first added to
bus
Battery 2
Disabled
Visible only for EXP-PSU.
Delete Expander
Enable Expander
Yes
Replace Expander